Care and cleaning
• Flat filter (C).
1. To unlock the filters (A) and (B), turn the
handle on the microfilter (B) approxi-
mately 1/4 counterclockwise and remove.
2. Hold the coarse filter (A) by the handle
and remove it from the microfilter (B).
3. Remove the flat filter (C) from the bot-
tom of the appliance.
4. Fully clean the filters with water.
5. Put the flat filter (C) to its initial posi-
tion. Make sure that it assembles correct-
ly in the two guides (D).
6. Put the coarse filter (A) in the microfilter
(B) and push the filters together.
7. Put the filters (A) and (B) in position.
Turn the handle on the microfilter (B)
clockwise until it locks in position.
To clean the spray arms
Do not remove the spray arms.
If the holes in the spray arms become clogged, remove remaining parts of soil with a
thin pointed object.
To clean the external surfaces
Clean the external surfaces of the appliance and control panel with a moist soft cloth.
Only use neutral detergents.
Do not use abrasive products, abrasive cleaning pads or solvents (acetone).
A
A
B
B
C
C
D