Refrigerant Cycle Diagrams - LG LV-B1864CL Product Data

Ceiling & floor 50hz, r22, ceiling suspended 50hz, r22
Hide thumbs Also See for LV-B1864CL:
Table of Contents

Advertisement

8. Refrigerant Cycle Diagrams

Model No.: LV-B18(24)64CL, LV-B2860CL
Model No.
LV-B1864CL
LV-B2464CL
LV-B2860CL
Model No.: LV-B18(24)64H(B)L, LV-B2860HL
Model No.
LV-B1864H(B)L
LV-B2464H(B)L
LV-B2860HL
36
Ceiling & Floor, Ceiling Suspended (50Hz, R22)
INDOOR UNIT
LIQUID SIDE
INDOOR
COIL
GAS SIDE
Pipe size(Diameter:Ø)
(inch)
Gas
Liquid
1/2"
1/4"
5/8"
1/4"
5/8"
3/8"
INDOOR UNIT
LIQUID SIDE
INDOOR
COIL
GAS SIDE
Pipe size(Diameter:Ø)
(inch)
Gas
Liquid
1/2"
1/4"
5/8"
1/4"
5/8"
3/8"
OUTDOOR UNIT
CAPILLARY TUBE
OUTDOOR
COIL
COMPRESSOR
Piping length(m)
Rated
Max
7.5
15
7.5
20
5
20
OUTDOOR UNIT
CAPILLARY TUBE
CHECK VALVE
CAPILLARY TUBE
OUTDOOR
COIL
REVERSING
VALVE
COMPRESSOR
Piping length(m)
Rated
Max
7.5
15
7.5
20
5
20
: COOLING
Elevation(m)
Rated
Max
5
8
5
8
5
8
: COOLING
: HEATING
Elevation(m)
Rated
Max
5
8
5
8
5
8

Hide quick links: