Prem-I-Air PAC1130 Instruction Manual page 13

Mobile air conditioner
Table of Contents

Advertisement

6. Modes operation
Automatic Mode
1. When the Auto mode is selected, the indoor temperature sensor
operates automatically to select the desired mode: Cool, Fan or
Heat.
2. When the room temperature ≥24
selects cooling mode and the upper fan turns to low speed
automatically.
3. When the room temperature >22
automatically selects fan mode and the upper fan turns to low
speed automatically.
4. When the room temperature ≤22
selects heat mode and the upper fan turns to low speed
automatically.
Dehumidification Mode
1. The upper fan will run at low speed, the speed is not adjustable.
2. The compressor and lower fan runs will stop running after 8
minutes, then run again after 6 minutes automatically.
3. Temperature control is inoperative in dehumidification.
Cooling Mode
1. When the room temperature is higher than set temperature. The
compressor starts to run.
2. When the room temperature is lower than set temperature, the
compressor stops and upper fan operates at original set speed.
Fan Mode
1. The upper fan runs at set speed, the compressor and lower fan
motor stop.
2. The temperature is not adjustable.
Heat Mode
1. When the room temperature is higher than the set temperature,
the unit will not function.
2. When the room temperature is lower than the set temperature,
the heat function will operate.
3. To avoid cold air blowing out, the unit is equipped with an
automatic cold air cut-out.
U
s
e
o
f
C
o
n
t
r
o
l
U
s
e
o
f
C
o
n
t
r
o
l
(continued)
O
- 13 -
P
a
n
e
l
P
a
n
e
l
O
C, the unit automatically
C and ≤23
O
C, the unit
O
C, the unit automatically

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pac1140

Table of Contents