Whirlpool W11296289 Service Manual page 22

Provides the in-home service professional with service information for the “whripool, maytag, amana, and ikea refrigerators
Table of Contents

Advertisement

DIAGNOSTICS
AMB
70°
90°
110°
70°
90°
110°
Compressor Options - Refer To Applicable Design
(Oil cooler not present on all compressors)
PROCESS TUBE
EG SERIES
Service Key Assignment
O
O
LED1
LED2
LED3
SW1
During the first five minutes after a power on, put setting temperature at the minimum position for both RC and FC.
Afterward, hold "FREEZER TEMP" and "ICE TYPE" keys for 3 seconds to enter service mode.
After entering service mode, all LEDs will turn on to verify all LEDs can turn on.
To proceed to service steps, a user shall press all 5 keys individually from left to right to turn off all LEDs and validate touch function.
NOTE: For smooth operation of user interface key activation, wait at least 1 second between each press, to let the system toggle
between service steps.
KEYS
SW2 = Light Key
SW4 = Lock Key
SW5 = RC Temp Key
NOTE: For IDI model with twist tray ice maker, upon entry into service, an ice maker is enabled and a homing operation is performed,
this is to avoid of any other load interference when SANKYO IM is performing the Homing operation.
The LEDs on the FREEZER TEMP section will show the step number while the LEDs above REFRIGERATION TEMP section will show the
feedback. Steps 29 to 35 apply only for models with twist tray maker in the door (IDI).
2-4
n
Whirlpool
, Maytag
®
For Service Technician Use Only
Performance Data * (Normal Operating Conditions)
Watts
140 +/- 20
150 +/- 20
170 +/- 20
120 +/- 20
130 +/- 20
140 +/- 20
EMBRACO
(OIL COOLER IS OPTIONAL)
O
O
O
LIGHT
LED4
LED5
SW2
, Amana
, & IKEA
Refrigerators
®
®
®
High Side
EG Series
95 +/- 20
135 +/- 20
185 +/- 20
EM3 Series
120 +/- 20
160 +/- 20
220 +/- 20
SUCTION TUBE
SUCTION TUBE
DISCHARGE
OIL COOLER
EM3 SERIES
O CRUSH
O
O CUBE
LOCK
SW3
SW4
DESCRIPTION
Increment Key: Advance to next step
Decrement Key: Go back to the previous step
Change Setting Key: Turn ON/OFF load, PAUSE/RUN specific test
System Pressure (PSIG)
EMBRACO
DISCHARGE TUBE
PROCESS TUBE
O
O
LED6
LED7
LED8
SW5
Low Side
- 7 To 3
- 4 To 3
- 2 To 4
- 6 To 3
- 4 To 3
- 2 To 4
O
O
LED10
LED9

Hide quick links: