4. External Speaker (Option)
4-1. KES-5
External speaker KES-5 can be installed for KCT-60.
■ Connection procedure
1. Remove the ACC. cap on the rear of the transceiver.
2. Connect the D-sub connector of the KCT-60 to the D-sub
15-pin terminal of the transceiver.
3. Insert the two crimp terminals of the KES-5 to pins 3 and
12 of the square plug.
4. Connect the square plug to the 15-pin connector of the
KCT-60.
Note:
You must set up using the KPG-141D(C).
Before the external speaker can be used, you must as-
sign one of the keys as "External Speaker", using the
KPG-141D(C).
Black/White lead
黑色 / 白色导线
5. Changing Serial Port Level
5-1. Change FNC1 (TXD) and FNC2 (RXD) of D-SUB
15-pin connector from TTL level to RS-232C
level
FNC1 (TXD /6pin ) and FNC2 (RXD /7pin ) of D-SUB 15-
pin connector are confi gured at the TTL level as the default
value. But you can change these serial port level to RS-
232C level through the RS-232C level converter IC (IC516)
by confi guring the port.
Remove the R664, R635 and R662 chip jumpers and sol-
der the chip jumpers to R666, R633 and R665.
5-2. Change FNC1 (TXD), FNC2 (RXD), FNC3 (RTS)
and FNC4 (CTS) of D-SUB 15-pin connector
from TTL level to RS-232C level
FNC1 (TXD/6pin), FNC2 (RXD/7pin), FNC3 (RTS/8pin)
and FNC4 (CTS/9pin) of D-SUB 15-pin connector are con-
figured at the TTL level as the default value. But you can
change these serial port level to RS-232C level through the
RS-232C level converter IC (IC516) by confi guring the port.
Remove the R664, R635, R662, R659, R658 and R632
chip jumpers and solder the chip jumpers to R666, R633,
R665, R663, R660 and R630.
INSTALLATION / 安装
4. 外部扬声器 ( 选购件)
4-1. KES-5
■ 连接步骤
1. 拆下车载对讲机后部的 ACC. 盖。
2. 将 KCT-60 的 D-sub 连接器连接到车载对讲机的 D-sub 15
3. 将 KES-5 的两个压接式端子插入方形插头的针脚 3 和 12。
4. 将方形插头连接到 KCT-60 的 15 针连接器。
注意 :
13
10
7
4
1
14
11
8
5
2
15
12
9
6
3
KCT-60
12
Square plug
/ 方形插头
3
/ 黑色导线
Black lead
5. 改变串行接口电平
5-1. 将 FNC1 (TXD) 和 FNC2 (RXD) 的 D-SUB 15 针连接
接器被默认设置在 TTL 电平。但可以通过端口设置将这些串
行端口电平通过 RS-232C 档位转换器 IC (IC516) 转换至 RS-
232C 电平。
5-2. 将 D-SUB 15 针连接器的 FNC1 (TXD),FNC2 (RXD),
FNC3 (RTS/8 针 ) 和 FNC4 (CTS/9 针 ) 默认设置在 TTL 电平。
但可以通过端口设置将这些串行端口电平通过 RS -232C 档位
转换器 IC (IC516) 转换至 RS-232C 电平。
R633,R665,R663,R660 和 R630。
外部扬声器 KES-5 可安装于 KCT-60。
针端子。
必须使用 KPG-141D(C) 进行设置。
必须使用 KPG -141D( C) 将某个键指定为"外部扬声器" ,
方可使用外部扬声器。
器从 TTL 电平转换到 RS-232C 电平
FNC1 (TXD/6 针 ) 和 FNC2 (RXD/7 针 ) 的 D-SUB 15 针连
从 R664,R635 和 R662 跳线至 R666,R633 和 R665。
FNC3 (RTS) 和 FNC4 (CTS) 从 TTL 电平转换到 RS-
232C 电平
D-SUB 15 针连接器的 FNC1 (TXD/6 针 ),FNC2 (RXD/7 针 ),
从 R664, R635, R662,R659,R658 和 R632 跳 线 至 R666,