Item
8. QT Fine
1) TEST CH: Center, Low, High
Deviation
(3 points)
[Wide 5k]
Deviation meter filter
LPF: 3kHz, HPF: OFF
PTT: ON
[Wide 4k]
2) TEST CH: Center
PTT: ON
[Narrow]
3) TEST CH: Center
PTT: ON
9. DQT Fine
1) TEST CH: Center, Low, High
Deviation
(3 points)
[Wide 5k]
Deviation meter filter
LPF: 3kHz, HPF: OFF
PTT: ON
[Wide 4k]
2) TEST CH: Center
PTT: ON
[Narrow]
3) TEST CH: Center
PTT: ON
10. Single Tone
1) TEST CH: Center , Low, High
Fine Deviation
Deviation meter filter
[Wide 5k]
LPF: 15kHz, HPF: OFF
PTT: ON
[Wide 4k]
2) TEST CH: Center
PTT: ON
[Narrow]
3) TEST CH: Center
PTT: ON
11. DTMF Fine
1) TEST CH: Center, Low, High
Deviation
Deviation meter filter
[Wide 5k]
LPF: 15kHz, HPF: OFF
PTT: ON
[Wide 4k]
2) TEST CH: Center
PTT: ON
[Narrow]
3) TEST CH: Center
PTT: ON
12. MSK Fine
1) TEST CH: Center, Low, High
Deviation
(3 points)
[Wide 5k]
Deviation meter filter
LPF: 15kHz, HPF: OFF
PTT: ON
[Wide 4k]
2) TEST CH: Center
PTT: ON
[Narrow]
3) TEST CH: Center
PTT: ON
13. Battery Warning
1) BATT terminal voltage: 5.9V
Level
PTT: ON
Writing
Measurement
Condition
Test.equipment
Power meter
Deviation meter
Oscilloscope
AG
AF VTVM
SSG
DVM
TK-3260EX
Adjustment
Terminal
Parts
Method
ANT
FPU
0.80kHz
SP/MIC
connector
0.60kHz
0.40kHz
0.75kHz
0.60kHz
0.35kHz
3.0kHz
2.4kHz
1.5kHz
3.0kHz
2.4kHz
1.5kHz
3.0kHz
2.4kHz
1.5kHz
ANT
Write
BATT
termina
Specifications./.Remarks
±40Hz
±40Hz
±40Hz
±40Hz
±40Hz
±40Hz
±100Hz
±100Hz
±100Hz
±100Hz
±100Hz
±100Hz
±100Hz
±100Hz
±100Hz
BATT terminal voltage:
5.9V
11