Sensor low battery. This condition occurs if a system sensor has a low battery. The
sensor may still be communicating with the panel. Trouble beeps will start and the
STATUS button will light. Press the STATUS button and the display will show what
sensors have a low battery. You may need to call your security system dealer to resolve
this problem. Some sensor batteries can be replaced by the homeowner.
Fail-to-communicate. This condition occurs if your security system cannot
communicate to the central monitoring station. Your system will try to report to the
central monitoring station eight times before it tells you there is a fail-to-communicate
problem. Trouble beeps will start and the STATUS button will light. Press the STATUS
button and the display will show Comm Test Fail or Comm Failure. You may need to
call your security system dealer if the problem continues.
Sensor open. This condition occurs if a door or window is open or a system sensor has
been disturbed and not reset properly. For example, a door/window sensor magnet may
have been removed from the sensor. Your system will indicate this condition to you by
causing the STATUS button to light. When you press the STATUS button, the display
shows, for example, Sn 1 Front Door Open. Correct the problem by resetting the
sensor. If this condition continues, call your security system dealer.
Sensor tampered. This condition occurs when a sensor is physically tampered with, for
example, the cover is taken off of one of the sensors. If the system is armed an alarm
will occur. Your system will indicate this condition to you by causing the STATUS button
to light. Trouble beeps will start. Press the STATUS button and the display shows Sn #
Name Tampered. Correct the problem by resetting the sensor. If this condition
continues, call your security system dealer.
RF jam detected. The panel receiver may be experiencing some interference. The
system will call to notify the central monitoring station about this problem.
Clearing status. Some types of status conditions, such as the alarm history, must be
cleared manually. To clear system status, press the STATUS button, read and/or listen
to the status messages, then press DISARM. If the trouble condition was a low system
battery, perform a sensor test. The STATUS light should turn off if all trouble conditions
have been corrected.