Download Print this page

Honeywell Lyric SIXSIREN Quick Installation Manual page 2

Peripheral siren

Advertisement

NOTE: After enrolling and before mounting
permanently, conduct Go/No Go tests (see controller's
instructions) to verify adequate signal strength. Adjust
the device location and orientation as necessary.
FC: NOTE: After enrolling and before mounting
permanently, conduct Go/No Go tests (see controller's
instructions) to verify adequate signal strength. Adjust
the device location and orientation as necessary.
SP: NOTE: After enrolling and before mounting
permanently, conduct Go/No Go tests (see controller's
instructions) to verify adequate signal strength. Adjust
the device location and orientation as necessary.
PA: NOTE: After enrolling and before mounting
permanently, conduct Go/No Go tests (see controller's
instructions) to verify adequate signal strength. Adjust
the device location and orientation as necessary.
Consult the Controller's instructions to
program the Siren Services: Siren Chime
mode sound level; Tamper, and Temperature
Sensing.
FC: Consult the Controller's instructions to
program the Siren Services: Siren Chime
mode sound level; Tamper, and Temperature
Sensing.
SP: Consult the Controller's instructions to
program the Siren Services: Siren Chime
mode sound level; Tamper, and Temperature
Sensing.
PA: Consult the Controller's instructions to
program the Siren Services: Siren Chime
mode sound level; Tamper, and Temperature
Sensing.
Approval Listings:
Specifications:
FCC / IC
Range: 0'- 25'/ 0 – 7.6m; Selectable
ETL Listed to UL985 / UL1023
RF Frequency: 2.4GHz
cETL Listed to ULC-S545 &
Batteries: 4 x 1.5V, AA Lithium; Honeywell 462
Tamper: Cover and Wall
ULC/ORD-C1023
Operating Temperature: 32° – 122° F / 0° – 50° C (Agency
RoHS
Compliance 32° – 120° F / 0° – 49° C)
Relative Humidity: 95% max. (Agency Compliance - 93% max.),
non-condensing
Dimensions: 3.78" Diameter x 1.14" Thick / 96 mm Diameter
x 29mm Thick
Product must be tested at least once each year / Le fonctionnement du produit doit
être vérifié au moins une fois par année / El producto debe ser probado al menos
una vez al año / O produto deve ser testado pelo menos uma vez por ano
 2014 Honeywell International Inc. Honeywell and is a registered trademark of Honeywell International Inc.
All other trademarks are the properties of their respective owners. All rights reserved
www.honeywell.com/security
Mount
/ Mount /
Mount / Mount
35dB
1
55dB
85dB
2
1
Factory default / Valeurs par défaut du
fabricant / Defecto de fábrica / Padrão
de fábrica
2
Life Safety
/ Life Safety / Life Safety /
Life Safety
Program
/
Program / Program
BATTERY CAUTION: Risk of fire,
explosion and burns. Do not recharge,
disassemble, heat above 212° F
(100° C) or incinerate. Dispose of
used batteries properly. Keep away
from children.
FC: BATTERY CAUTION: Risk of fire,
explosion and burns. Do not recharge,
disassemble, heat above 212° F
(100° C) or incinerate. Dispose of
used batteries promptly. Keep away
from children.
SP: BATTERY CAUTION: Risk of fire,
explosion and burns. Do not recharge,
disassemble, heat above 212° F
(100° C) or incinerate. Dispose of
used batteries promptly. Keep away
from children.
PA: BATTERY CAUTION: Risk of fire,
explosion and burns. Do not recharge,
disassemble, heat above 212° F
(100° C) or incinerate. Dispose of
used batteries promptly. Keep away
from children.
Support / Support / Support / Support
https://mywebtech.honeywell.com/
U.S. warranty / U.S. warranty / U.S. garantie / U.S. garantia
www.honeywell.com/security/hsc/resources/wa
FEDERAL COMMUNICATIONS COMMISSION & INDUSTRY CANADA STATEMENTS
The user shall not make any changes or modifications to the equipment unless authorized by the Installation
Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the
equipment.
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules, and RSS-210 of Industry Canada. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS-210 des Industries Canada. Son fonctionnement
est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d'interférences nuisibles. (2) Cet appareil doit
accepter toute interférence reçue y compris les interférences causant une reception indésirable.
RF Exposure
Warning – The antenna(s) used for this device must be installed to provide a separation distance of at least 7.8 inches
(20 cm) from all persons and must not be co-located or operating in conjunction with any other antenna or
transmitter except in accordance with FCC multi-transmitter product procedures.
Mise en Garde
Exposition aux Frequences Radio: L'antenne (s) utilisée pour cet émetteur doit être installée à une distance de
séparation d'au moins 7,8 pouces (20 cm) de toutes les personnes.
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE
IS USED, FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM.
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Replace Battery
/
Replace Battery / Replace Battery
MyWebTech
Warranty
Ê800-15964kŠ
800-15964 11/15 Rev B BETA2

Advertisement

loading