RS-232 Protocol
SIGNAL GENERATOR
PIN
ASSIGNMENT
1
NC
2
TxD
3
RxD
4
NC
5
GND
6
NC
7
NC
8
NC
9
NC
Telnet Control
Before attempting to use Telnet control, please ensure that both the unit and the PC/laptop are connected to the same active network.
To Access Telnet
In Windows XP
In Windows 7
In Mac OS X
Once in the Command Line Interface (CLI) type "telnet" followed by the IP address of the unit (and the port number if it is non-standard)
and then hit "Enter". This will connect us to the unit we wish to control.
NOTES: The default IP address is 192.168.1.50. If the IP address is changed then the IP address required for Telnet access will also
change accordingly.
PIN
1
2
3
4
5
6
7
8
9
Click Start, type "cmd" in the search field, and press ENTER.
Click Start > Run, type "cmd" in the search field, and press ENTER.
Click Go > Applications > Utilities > Terminal.
REMOTE CONTROL
ASSIGNMENT
NC
RxD
TxD
NC
GND
NC
NC
NC
NC
5
RS-232 & Telnet Control
Baud Rate: 115200bps
Data Bits: 8
Parity: None
Flow Control: None