7.3
Operating Time related Inspections
After 5 Operating hours
After 25 Operating hours
Every 50 Operating hours
Every 100 Operating hours
Every 200 Operating hours
Every 500 Operating hours
7.3.1 After the first 5 Operating Hours
• Check valve clearance, replace cylinder head cover gasket as necessary.
7.3.2 After the first 25 Operating Hours
•
Work as specified in section 7.3.3
7.3.3 Every 50 Operating Hours
•
Check fuel, lubrication and cooling system for leaks.
•
Clean engine.
•
Check all coolers and radiators for free passage of air – clean if necessary.
•
Check crankcase ventilation.
•
Check routing oft he turbocharger*) drain line (see section 8.13)
•
Clean induction air filter or replace, if necessary.
•
Check valve clearance, replace cylinder head cover gasket as necessary.
•
Check compression.
•
Clean and check spark plugs.
•
Check drive belt tension of generator and coolant pump.
•
Check the control cable and actuator rod for both the throttle and the boost limiter*) on the
turbocharger for freedom of movement, range of travel – lubricate.
•
Check emergency operation.
•
Check seating of electrical connectors and wire boots.
•
Check engine wiring for damage and proper routing.
•
Check condition of emergency battery (see section 8.15)
•
Check bolts, nuts, safety pins, and engine mounting frame for tight fit and proper condition.
•
Perform engine test run.
*)
L 2400 ET/DT/DX only
Edition: 20.06.2018
Operating Manual
L 2400 EF/DF/ET/DT/DX/DS
section
7.3.1
7.3.3
X
X
X
X
X
X
7.3.4
7.3.5
7.3.6
X
X
X
X
X
Page: 30/53