Engine Operating Trouble In Normal Mode, No Trouble In Emergency Mode - LIMBACH L 2400 EF Operating And Maintenance Manual

Engine for powered gliders and very light aircraft
Table of Contents

Advertisement

12.5 Engine Operating Trouble in Normal Mode, no Trouble in Emergency Mode

The following phenomena are considered to be engine operating trouble:
uneven and irregular engine run
temporary interruptions
low power
engine overheat
rough engine run
Possible Cause:
Speed sensor B1 (top mounted) defective.
Throttle potentiometer loose, maladjusted,
disconnected or defective.
Coolant temperature sensor defective.
Air temperature sensor defective.
Wiring harness or connector loose or defec-
tive, wire broken in wiring harness.
Edition: 20.06.2018
Operating Manual
L 2400 EF/DF/ET/DT/DX/DS
Remedy:
Replace speed sensor, restore gap distance
to pickup-pins on the flywheel.
Check poteniometer fastening, adjust if nec-
essary.
Note:
To adjust the throttle poteniometer a special
tool is necessary P/N 803.002.015.000 (only
for Weber Alpha).
Check wiring and/or connector repair or re-
place if necessary. Replace potentiometer if
necessary.
Check sensor, replace if necessary.
Check sensor, replace if necessary.
Check wiring harness and connectors, re-
pair if necessary.
Page: 53/53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L 2400etL 2400dfL 2400dtL 2400dxL 2400ds

Table of Contents