External control unit in the housing EV-G F24 R12 p. 28 Control for non Winkhaus access control systems p. 28 Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 4
Use of the day mode for permanently opening of the door p. 74 4.1.4 Instructions for switch day / night mode p. 74 Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Wireless remote control p. 89 Cable transition T-KÜ-T1 FT p. 90 8 Accessories and Classification 9 Declaration of performance Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
• only trained professionals should install the door furniture, locking units and accessory parts according to the installation instructions. Applicable DIN, EN standards and BauPVO are about to follow. Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Installation, Operating and blueMotion 5044745 Maintenance Instructions The stipulations of use as intended have been met, once the Winkhaus fittings are: • installed according to their defined purpose and installation specifications, • not used in another way than described, • maintained and cared for at regular intervals as instructed, •...
Danger to life or danger of serious injuries. CAUTION! Danger of material damage. Notice: Useful information and tips. Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
• Arbitrary modifications, changes or makeshift repairs are not permitted due to concerns for safety. You must only use genuine Winkhaus parts for replacements. • The manufacturer shall only be held liable for security related properties of...
Power supply JY(ST)Y Cable type Alternating current Direct current Make contact Break contact NO-NC Changer contact Uninterruptible power supply Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Figure 2-1: Locking system blueMotion with accessories (e.g. external control unit in switch box) and external power supply Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 12
Figure 2-2: Locking system blueMotion with accessories (e.g. external control unit in the housing EV-G in the sash) and frame power supply 24 V DC Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 13
Figure 2-2: T-KÜ-T1 RT KABEL 0,6M RNT with plug connection to the frame power supply 24 V DC (optional) Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 14
*** Realization of the day function in conjunction with daytime latch, electric strike with day release or with roller latch Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
FZG anti-barricade function and mounted in conjunction with a battery (Article No. 2121455) for system zeroing. Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 16
5051573 T-BM-F2069 L13/65 92/10 M2 MC 5046018 T-BM-F2460 L03/35 92/8 M2 MC 2194929 T-BM-F2460 L03/35 92/10 M2 EST Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 17
5046036 T-BM-U2471 L03/35 92/10 M2 MC 2196799 T-BM-U2471 L03/35 92/10 M2 EST 4940872 T-BM-U2471 L03/45 92/8 M2 MC Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 18
5047898 T-BM-EN1125-U2460 L36/40S 92/9 M2 MC 5047899 T-BM-EN1125-U2460 L36/45S 92/9 M2 MC 5033451 T-BM-EN1125-U2460 L36/65S 92/9 M2 MC Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
T-Grt. SL U26-192 ... Please always do include the following specifica- tions when placing your order: DIN-right- handed or left-handed Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
PVCu / plastic or aluminum) conceals the routing for the required cable reserves to prevent possible cable dama- Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Cover plate for sash, flat faceplate 20 mm, round ends R10, length 130 mm, suitable for timber (PVCu if necessary) Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
• of chromium-plated steel • concealed in the rebate Notice: Cable continuous, not separable. 2126942 T-HT KÜ M1188 Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
• Power supply 24 V DC (stabilized) • min. 1,5 A continuous current (min. 2 A peak current) • min. 36 W Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Use cable grommet at 230 V cable (2 x included)! No external voltage on output for external signals. Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
CAUTION! The antipanic version panicLock blueMotion EN 179 / 1125, must always be mounted with a battery for system zeroing. Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
• mounting of the external control unit on the inside 2194689 T-CONTROL FOR NON WINKHAUS ACCESS CONTROL SYSTEMS Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 29
T-KÜ-T1 FT 3,5 M, e.g. with cable transition T-HT KÜ M1188. 2522881 T-HT CONNECTION CABLE 6 M FOR MOTOR Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Maintenance Instructions 3 Installation 3.1 Routing details Routing for a standard triple-point lock are required to install the blueMotion motorised multipoint locking system. In addition, routings for the motor housing are required as indicated in the following diagrams. Notice: The magnetic bush has to be ordered separately.
Page 31
± 30°, in each case with smooth-running "free to turn" function. Figure 3.1-1: Dimensions for multipoint locking blueMotion Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Figure 3.2-1: Situation Magnetic bush / motor housing of PVC profile Figure 3.2-2: Situation Magnetic bush / motor housing of timber profile Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Recommendation: For hollow chamber / cable reserve in timber front doors, mill out pocket of approx. 50 mm x 95 mm. Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 34
245 mm vertical under the frame part drill hole of Ø 8 mm, depends on the profile/hinge rotation point) and for screw pre-drill (Ø 2,5 mm) Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 35
Insulate the wires not used! Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 36
Cover plate for T-KÜ-T1 FT Figure 3.3.1-5: Routing dimensions for T-KÜ-T1 FT + RT and cover plate F16 / F20 in timber Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Depending on the door-condition (open / closed) the unlocking or locking happens afterwards. Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 40
** be sure to insulate wires 230 V AC Figure 3.4-1: Overview installing the external control unit Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 41
24 V / 2,5 A to / from the motor housing Figure 3.4-2: Installing the external control unit with power supply Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 42
17 = + 24 V DC (white); 18 = GND (brown); 19 = RX (green); 20 = TX (yellow) Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 43
Reset button of the error counter 11.4 Plug RS / LS optional for use as reset button of the error counter (parallel 11.3 Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 44
The circuit is made via the output swing door drive (Terminals 6 - 8). Figure 3.4-4: Installation external control unit with LED Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 45
(RSK)! Installation sequence • Prior to installing the blueMotion unit, connect the sash cable of the cable transition "T-KÜ-T1 FT ..." or "T-Connection cable 6 m ..." to the motor housing.
Page 46
• In another switch box you can mount the changeover switch for day / night service (on customer request). • If you have chosen to use the Winkhaus wireless receiver can this install it in the same switch box (see installing the wireless receiver).
Page 47
Mains connection supplied by the costumer 230 V AC, 50 Hz Figure 3.4-4: Installing the power supply unit (stabilized) - external control unit Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 48
Mains connection supplied by the costumer 230 V AC, 50 Hz Figure 3.4-5: Installing the battery - power supply unit - external control unit Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
• The external control unit should preferably be housed in a 65 mm deep switch box (on the inside) (see Installing the external control unit). Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
• We recommend installing the receiver on the protected inside of the door to prevent manipulations to the receiver! Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
P1 button green LED red LED buzzer relay jumper 12 V / 24 V Figure 3.6.1-1: Installing the wireless receiver Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 52
"Make contact (NO)", from the wireless receiver to the "Open" button of the external control unit (terminal 12) "12 V DC resp. 24 V DC", power supply, e.g. from Winkhaus power supply unit (connect with white wire of the cable transition) "0 V DC", power supply, e.g.
Notice: Pay attention to the relevant installation instructions for additional use! • Put the cover back on the housing and lock and screw it down. Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 54
• Relay remains active after being activated per remote control. • Deactivation by actuating the remote control once more. Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
1 sec. it will be deactivated automatically. Figure 3.6.2-3: Setting the K4 relay 3.7 Connection of swing door drive The application of the blueMotion lock is generally suitable for swing door dri- ves. Notice: When using the transponder set blueMotion "T-CONTROL + TRANSPONDER SET T01"...
Page 56
Figure 3.7-1: Wiring plan blueMotion with swing door opener GEZE TSA 160 and EMD Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen...
Page 57
T-HT POWER SUPPLY 12 V DC / 2 A Antenna EAV / blueMotion Figure 3.7-2: Wiring plan blueMotion with swing door opener and transponder set Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 58
Do not connect a transponder antenna here. For blueMotion + swing door drive and transponders the following parts are be used: • T-CONTROL FOR NON WINKHAUS ACS (2194689) •...
3.8.1 Non Winkhaus access control system ACS general (frame- and sash side) If the blueMotion multipoint lock is used for others, as the aforementioned sys- tems (such as transponder set, remote control), note the following points: • We recommend the Winkhaus power supply T-HT NETZTEIL 24 V DC / 2,5 A (Art.-No.
Page 60
Figure 3.8.2-1: Wiring blueMotion with fingerprint ekey Integra micro with App (sash side), applies to fingerprint / keypad Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 61
Figure 3.8.2-2: Wiring blueMotion with fingerprint ekey Integra micro with App and frame power supply (sash side), applies to fingerprint / keypad Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 62
AR to control unit ekey home SE micro plus Figure 3.8.2-3: Wiring blueMotion with fingerprint ekey Arte micro plus with App (sash side) Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 63
Figure 3.8.2-4: Wiring blueMotion with fingerprint ekey Arte micro plus with App and frame power supply (sash side) Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 64
Figure 3.8.2-5: Wiring blueMotion with fingerprint ekey Integra with control unit (sash side) Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 65
24 V DC 1 A (2 A/2 S) (Art.-No. 5038589) Figure 3.8.2-6: Wiring blueMotion with fingerprint ekey Integra with control unit and frame power supply (sash side) Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 66
SE integra plus 1 Artikel -Nr. on request Figure 3.8.2-7: Wiring blueMotion with fingerprint ekey Arte with control unit (sash side) Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 67
1 Figure 3.8.2-8: Wiring blueMotion with fingerprint ekey Arte with control unit and frame power supply (sash side) Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 68
(IDENCOM Art.-No. 680 804) Figure 3.8.2-9: Wiring blueMotion with fingerprint IDENCOM BioKey INSIDE (sash side) Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 69
(IDENCOM Art.-No. 680 804) Figure 3.8.2-10: Wiring blueMotion with fingerprint IDENCOM BioKey INSIDE and frame power supply (sash side) Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 70
T-BM ... including motor housing, Artikel-No. on request Figure 3.8.2-11: Wiring blueMotion without external access control system (sash side) Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 71
(2 A/2 S) (Art.-No. 5038589) Figure 3.8.2-12: Wiring blueMotion without external access control system with frame power supply (sash side) Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
(break / normally closed contact) or 7 / 8 (make / normally open contact) of the external control unit. • Screw together the housing again. Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
• via the button • via the intercom (floating contact button!) • via the handle and the key Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
The standard adjustment of the blueMotion External control unit at delivery / without the use of day / night switch is the night mode. Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
• If a transponder chip is unknown to the control, access will be denied. Action Acoustic signal Result Door with transponder not authorized nnnnn "Open" short, long Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 76
(no more transponders (no more transponders can be tutored) sion over the antenna can be tutored) Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 77
If you lose the cards, the external control unit will have to be exchanged in its entirety. Please contact customer service for more information. Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
LED red Key A Key B Notice: Press and hold the key until you can hear the acoustic signal! Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 79
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 80
• Insert two Lithium CR 2016 batteries. Notice: Pay attention to the polarity! ECO-WATCH: Properly dispose of the batteries! Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 81
• A wireless remote control that has not been taught will be programmed (see "Teaching wireless remote control directly via the remote control"). Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
4.4 Wireless receiver for additional applications (e.g. Garage door control units) No. Name jumper JP1 P1 key K4 relay red LED green LED Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 83
No additional wireless remote control can be saved. This is indicated in the teach-in mode by both LED displays flashing simultaneously three times. Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
• If you are using the battery, pay attention to the recommended service life. • Clean electronic parts only in a dry state. Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
(reset of the error counter)! Important: The error counter is blank, but if necessary not cause of error. Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 86
• check cable transition • profile cylinder • check profile cylinder for without free free moving cam moving cam Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 87
No neutral position • battery is out of • replace the battery in the event of a function power outage. Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
90 x 72 (= 4 TE) x 58 mm Weight: approx. 0.2 kg Installation: top hat rail mounting Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Frequency: 433.92 MHz Number of code combiations: 2 to the power of 64 (as "Rolling Code") Modulation: AM / ASK Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
• T-KÜ-T1 FT 2 M with 2 m cable + plug for motor housing • T-KÜ-T1 FT 3,5 M with 3.5 m cable + plug for motor housing Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 91
Cable transition T-HT KÜ M1188 Dimensions: 20 x 382 x 15 mm flexible length of spiral: 241 mm Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Wireless receiver (separate), e.g. for cou- pling with the garage door control unit (use the 2. button at the wireless remote control) Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 93
U ≥ 22 x 6 mm b) c) Maximum door sash height: 2500 mm Maximum door sash width: 1500 mm Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 94
An emergency power back up must ensure that the bolt always reaches the end position in the event of a power failure. Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 95
Signed for and on behalf of the manufacturer by: Meiningen, 17/02/2015 ppa. Dr. D. Warnow, Technical Director ppa. A. Dinkelborg, Director of Product Management Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes...
Page 96
Dr. D. Warnow, Technical Director ppa. A. Dinkelborg, Director of Product Management Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen ∙ T +49 369 3950 - 0 ∙ tuerverriegelung@winkhaus.de ∙ www.winkhaus.de STV SB February 2017 · EN · All rights reserved.
Page 97
Dr. D. Warnow, Technical Director ppa. A. Dinkelborg, Director of Product Management Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen ∙ T +49 369 3950 - 0 ∙ tuerverriegelung@winkhaus.de ∙ www.winkhaus.de STV SB February 2017 · EN · All rights reserved.
Page 98
Aug. Winkhaus GmbH & Co. KG Berkeser Straße 6 D-98617 Meiningen T +49 3693 950- 0 F +49 3693 950- 134 winkhaus.de tuerverriegelung@winkhaus.de T SB June 2018 Print-No. 5044745 · EN · All rights and changes reserved.
Need help?
Do you have a question about the blueMotion and is the answer not in the manual?
Questions and answers