Technical Data; Assembly, Set-Up And Installation; Hazard Warnings; Installation Instructions - Toro TS120 Operating Manual

Pop-up impact sprinkler
Hide thumbs Also See for TS120:
Table of Contents

Advertisement

4. Technical data

Recommended operating pressure
Permitted operating pressure
WARNING!
Connection thread:
Liquids:
Liquid temperature:
Ambient temperature:
For further data see separate data sheet.

5. Assembly, set-up and installation

5.1 Hazard warnings

!
If any impurities get into the sprinkler, it is possible that the sprinkler could be destroyed
and that fitters could be injured. Flush out the line thoroughly before connecting the water
supply.
!
Any unexpected emergence of a jet of water can lead to serious injury.
Make sure that the installation has been fully completed before turning on the water supply.

5.2 Installation instructions

The thread connection on the pop-up sprinkler is 1½" NPT.
For the thread seal, use hemp and sealing compound, e.g. Fermit Spezial or teflon tape.
The pop-up sprinkler should be fitted in accordance with the 'Triton-L pop-up sprinkler installation
diagram' (see next page). In order to avoid any load pressure on the main line, you should definitely
use a flexible connection.
Providing a drainage pit directly connected to the drainage, as shown in the installation diagram, is
strongly recommended.
For screwing in the connection joint the housing or housing edge of the pop-up sprinkler can be
firmly held or clamped.
6
72.5 to 116 psi
43.5 to 145 psi
The pressure at the sprinkler must not exceed 145 psi.
G1½" NPT
Water
104° F max.
140° F max.