Technical Parameter; General Parameter; Electrical Parameter; Transmitting Current - Ebyte E01 Series User Manual

Nrf24l01p wireless module
Table of Contents

Advertisement

nRF24L01P wireless module

1. Technical Parameter

1.1.

General parameter

Model
Core IC
E01-ML01D
nRF24L01P
E01-ML01DP4
nRF24L01P
E01-ML01DP5
nRF24L01P
E01-2G4M27D
nRF24L01P
E01-ML01IPX
nRF24L01P
E01-ML01S
nRF24L01P
E01-ML01SP2
nRF24L01P
E01-ML01SP4
nRF24L01P
1.2.

Electrical parameter

1.2.1. Transmitting current

Model
E01-ML01D
E01-ML01DP4
E01-ML01DP5
E01-2G4M27D@3.3V
E01-2G4M27D@5.0V
E01-ML01IPX
E01-ML01S
E01-ML01SP2
E01-ML01SP4

1.2.2. Receiving current

Model
E01-ML01D
E01-ML01DP4
E01-ML01DP5
E01-2G4M27D@3.3V
E01-2G4M27D@5.0V
E01-ML01IPX
E01-ML01S
E01-ML01SP2
E01-ML01SP4
Copyright ©2012–2017,Chengdu Ebyte Electronic Technology Co.,Ltd.
3
Size
12.6 * 22.6 mm
15 * 27 mm
18 * 33.4 mm
18 * 33.4 mm
12 * 19 mm
12 * 19 mm
12.8 * 25 mm
14.8 * 18 mm
Min
Typ
Max
12
13
100
110
120
120
130
140
480
490
500
380
390
400
12
13
12
13
120
130
140
110
120
130
Min
Typ
Max
11
12
18
20
18
20
22
23
21
22
11
12
11
12
19
21
24
26
Operating
Net Weight
Temperature
1.1±0.1g
-40 ~ 85°C
1.4±0.1g
-40 ~ 85°C
4.9±0.1g
-40 ~ 85°C
5.1±0.1g
-40 ~ 85°C
0.6±0.1g
-40 ~ 85°C
0.5±0.1g
-40 ~ 85°C
0.8±0.1g
-40 ~ 85°C
1.2±0.1g
-40 ~ 85°C
Unit
14
mA
mA
●When designing current supply circuit, 30% margin is recommended
to be remained so as to ensure long-term stable operation of the
mA
whole module;
mA
●The current at the instant of transmitting may be high, but the total
mA
energy consumed may be lower due to very short transmitting time;
14
mA
●When using external antenna, the impedance matching degree at
different frequency points between antenna and module may affect
14
mA
the transmitting current value at different levels.
mA
mA
Unit
13
mA
22
mA
●The current consumed when the RF chip is only working at receiving
22
mA
mode is called as receiving current,the tested receiving current may
24
mA
be higher for some RF chips with communication protocol or the
23
mA
developers have loaded their own protocol to the whole module;
13
mA
● The current at pure receiving mode will be mA level, users can
realize µA level of receiving current through firmware development.
13
mA
23
mA
28
mA
E01 series user manual
Operating
Storage
Humidity
Temperature
10% ~ 90%
-40 ~ 125°C
10% ~ 90%
-40 ~ 125°C
10% ~ 90%
-40 ~ 125°C
10% ~ 90%
-40 ~ 125°C
10% ~ 90%
-40 ~ 125°C
10% ~ 90%
-40 ~ 125°C
10% ~ 90%
-40 ~ 125°C
10% ~ 90%
-40 ~ 125°C
Remarks
Remarks