Mitsubishi Electric FR-PA07 Instruction Manual

Enclosure surface operation panel

Advertisement

Quick Links

INVERTER
Enclosure surface operation panel
FR-PA07
Thank you for purchasing the enclosure surface operation panel (FR-PA07). This instruction manual
gives handling information and precautions for use of this equipment. Incorrect handling might
cause an unexpected fault. Before using the equipment, please read this manual carefully to use the
equipment to its optimum performance.
Please forward this instruction manual to the end user.
This product is an option dedicated for the FR-E700 series.
Refer to the inverter unit's instruction manual for details on the operation panel functions, operation
methods and handling methods.
Operate the keys with dry hands to prevent an electric shock.
Do not install and operate the enclosure surface operation panel (FR-PA07) if it is damaged
or has parts missing.
Provide a safety backup device, such as an emergency brake, to protect machines and
equipment from hazardous conditions if the enclosure surface operation panel (FR-PA07)
becomes faulty.
To prevent damage from static electricity, touch a piece of metal nearby before touching this
product to remove any body static electricity.
1. Instructions
For the FR-E700 series inverters manufactured during or before the period shown by the
following serial numbers, there are restrictions mentioned below.
1) Parameter copy (
verification) does not function. Display turns into the reading indication, but reading is
not executed. If writing or verification is executed, an error occurs.
2) Initial value change list (
3) Easy setting mode (press
change the operation mode.
4) SERIAL number check
Refer to the inverter manual for the position of the rating plate.
Rating plate example
Symbol Year
Type
FR-E720-0.1K to 0.75K
FR-E720-1.5K to 5.5K
FR-E720-7.5K
FR-E720-11K, 15K
INSTRUCTION MANUAL

Safety precautions

) is displayed, but parameter copy (reading, writing, or
) cannot be used.
and
Month
Control number
SERIAL (Serial No.)
SERIAL number
J7
K7
L7
G7
simultaneously (0.5s)) cannot be used to
The SERIAL consists of 1 version symbol, 2
numeric characters or 1 numeric character and
1 alphabet letter indicating year and month, and
6 numeric characters indicating control number.
Month is indicated as 1 to 9, X (October), Y
(November), and Z (December).
Type
FR-E740-0.4K to 7.5K
SERIAL number
D7
1

Advertisement

loading

Summary of Contents for Mitsubishi Electric FR-PA07

  • Page 1: Safety Precautions

    Safety precautions Operate the keys with dry hands to prevent an electric shock. Do not install and operate the enclosure surface operation panel (FR-PA07) if it is damaged or has parts missing. Provide a safety backup device, such as an emergency brake, to protect machines and equipment from hazardous conditions if the enclosure surface operation panel (FR-PA07) becomes faulty.
  • Page 2 Stopper PU connector Stopper NOTE Install the FR-PA07 only when the front cover is installed. REMARKS For details of the connection cable (FR-CB20 ), refer to the connection cable (FR- CB20 ) instruction manual. 2.2 Removal when the connection cable (FR-CB20 ) is used...
  • Page 3: Names And Functions Of The Operation Panel (Fr-Pa07)

    3. Names and functions of the operation panel (FR-PA07) Unit indication Rotation direction display Hz: Lit to indicate frequency. A: Lit to indicate current. Indicates that forward rotation (Off to indicate voltage and operation is being performed. flicker to indicate set frequency Slow flickering (1.4s cycle):...
  • Page 4: Basic Operation

    4. Operation 4.1 Basic operation Operation mode switchover At powering on (external operation mode) Hz Hz Hz Hz PU Jog operation mode (Example) Hz Hz DE SET PU operation mode Value change and frequency flicker. (output frequency monitor) Frequency setting has been written and completed!! DE SET DE SET...
  • Page 5 4.2 Operation lock (Press [MODE] for a while (2s)) Operation using the setting dial and key of the FR-PA07 can be made invalid to prevent parameter change, and unexpected start or frequency setting. Set "10 or 11" in Pr. 161, then press for 2s to make the setting dial and key operation invalid.
  • Page 6: Use The Setting Dial Like A Potentiometer To Perform Operation

    4.3 Use the setting dial like a potentiometer to perform operation POINT Set "1" (setting dial potentiometer mode) in Pr. 161 Frequency setting/key lock operation selection. Changing example Changing the frequency from 0Hz to 60Hz during operation Operation Display Screen at powering on Hz Hz The monitor display appears.
  • Page 7: Standard Specifications

    5. Specifications 5.1 Standard specifications Item Specifications Ambient temperature -10°C to +50°C (non-freezing) Ambient humidity 90%RH or less (non-condensing) Storage temperature -20°C to +60°C Ambience Indoors (free from corrosive gas, flammable gas, oil mist, dust and dirt) Altitude, vibration Maximum 1000m above sea level for standard operation. 5.9m/s or less Power supply Power is supplied from the inverter.