Keystone OM11 - EPI2 DEvIcENEt INtErfacE
InstallatIon and maIntenance InstructIons
Before installation these instructions must be fully read and understood

table of contents

1. Introduction ................................................... 1
2. Operation and storage .................................. 1
3. Distinguish OLD/NEW models ..................... 1
4. Installation ..................................................... 3
4.1
US market) ........................................... 3
4.2
(US or NO US market) ......................... 5
5. communication features .............................. 6
6. DeviceNet interface module ......................... 6
6.1
On board indication ............................. 6
6.2
Wiring diagram .................................... 7
6.3
7. Brief DeviceNet description .......................... 8
7.1
Network cable ...................................... 8
7.2
terminator ........................................... 8
8. communication interface ............................. 9
8.1
actuator commands ............................ 9
8.2
8.2.1 Positioning algorithm ........................ 11
8.3
fail safe data...................................... 11
8.4
8.5
User defined data .............................. 11
8.6
configuration data ............................. 12
8.7
8.8
EDS file ............................................... 12
9. Local settings .............................................. 13
9.1
On-boards interface .......................... 13
9.2
DeviceNet MacID setting .................. 14
9.3
DeviceNet date rate setting .............. 14
11. DeviceNet certificate ................................... 14
12. Optional kits ................................................. 15

1 IntroductIon

the OM11 DeviceNet interface is an electronic
module that allows you to connect the Keystone
EPI2 electrical actuator to a DeviceNet network.
the module has its own microprocessor and
acts as a pure bus interface without affecting
the actuator control integrity. It is installed
inside the actuator housing and takes the
electrical power from the actuator power
supply module. the DeviceNet network is
fully isolated from the actuator electronics.
Emerson.com/FinalControl
for details about EPI2 actuator the reference
manual is: EPI2 Quarter-turn Electric
actuator IOM.
WarnIng
EPI2 actuators must be electrically isolated before
any disassembling or reassembling operations.
Before any disassembling or reassembling
operations, please follow in detail the relevant
paragraph of the basic installation and operating
manual (latest revision available).
WarnIng
The electronic parts of the EPI2 actuators and all
option modules can be damaged by a discharge
of static electricity. Before you start, touch a
grounded metal surface to discharge any static
electricity.
WarnIng
It is assumed that the installation, configuration,
commissioning, maintenance and repair works
are carried out by qualified personnel and
checked by responsible specialists.
WarnIng
Repair work, other than operations outlined in this
manual, is strictly reserved to qualified Emerson
personnel or to personnel authorized by the
company itself.

2 operatIon and storage

the module is designed to work and to be
stored in the same environment of the actuator.

3 dIstInguIsh old/neW Models

It is important to distinguish between EPI2/f02
old models and the new ones.
to install the board on base actuator, in fact, it
is necessary to choose the correct mechanical
parts form the kit.
furthermore, the meaning of some data
exchanged on the DeviceNet interface depends
on model (old or new); differences will be
explained in the following paragraphs.
© 2017 Emerson. All rights reserved.
figures below allow to distinguish old version
of EPI2/f02 from the new version (on the labels
are underlined the digits of Product Number);
furthermore, the logic boards with heatsink
identifies old version models, while logic boards
without heatsink identifies new version models.
VcIoM-02377-en 17/05

Advertisement

Table of Contents
loading

Summary of Contents for Emerson Keystone OM11

  • Page 1: Table Of Contents

    Keystone OM11 - EPI2 DEvIcENEt INtErfacE InstallatIon and maIntenance InstructIons Before installation these instructions must be fully read and understood table of contents for details about EPI2 actuator the reference figures below allow to distinguish old version manual is: EPI2 Quarter-turn Electric of EPI2/f02 from the new version (on the labels 1.
  • Page 2: Figure

    Keystone OM11 - EPI2 DEvIcENEt INtErfacE InstallatIon and maIntenance InstructIons fIgUrE 1 Label for NON US MarKEt - Digits X7X8 on product coding chart fIgUrE 2 Label for US MarKEt – Digit 6 on product coding chart fIgUrE 3 fIgUrE 4...
  • Page 3: Installation

    Keystone OM11 - EPI2 DEvIcENEt INtErfacE InstallatIon and maIntenance InstructIons 4 InstallatIon 4.1 assembling procedure for models 63-125 nm old version (us or no us market) to assemble the OM11 into the EPI2/f02 • Detect the black cable required for the...
  • Page 4 Keystone OM11 - EPI2 DEvIcENEt INtErfacE InstallatIon and maIntenance InstructIons fIgUrE 9 fIgUrE 12 • Unscrew the 3 screws (figure 9): 3 pcs M3x10 • Place the OM11 card onto the spacer and tighten the 4 screws (figure 12). fIgUrE 10 fIgUrE 13 •...
  • Page 5: Assembling Procedure For Models

    Keystone OM11 - EPI2 DEvIcENEt INtErfacE InstallatIon and maIntenance InstructIons 4.2 assembling procedure for models fIgUrE 16 250-500-1000-2000 nm old version (us or no us market) fIgUrE 14 • connect OM11 flat cable to connector on the logic board (figure 16).
  • Page 6: Communication Features

    Keystone OM11 - EPI2 DEvIcENEt INtErfacE InstallatIon and maIntenance InstructIons 5 coMMunIcatIon features communication protocol caN bus standard, 5 wires DeviceNet application Network topology Line / trunk-drop topology transmission medium Specific cable for DeviceNet network: 1 twisted pair for power,...
  • Page 7: Wiring Diagram

    Keystone OM11 - EPI2 DEvIcENEt INtErfacE InstallatIon and maIntenance InstructIons Mod_stat Module Status LED as defined in spec. vol. 3 ‘DeviceNet adaptation for cIP’, chapter 7 condition description No power there is no power applied to the device Operational green...
  • Page 8: Bus/Hardwired Mode Selection

    Keystone OM11 - EPI2 DEvIcENEt INtErfacE InstallatIon and maIntenance InstructIons 6.3 bus/hardwired mode selection • Support for up to 64 devices in a network • in the trunk line is normally used the thick the DeviceNet interface manages the bus/ (i.e.
  • Page 9: Communication Interface

    Keystone OM11 - EPI2 DEvIcENEt INtErfacE InstallatIon and maIntenance InstructIons 8 coMMunIcatIon Interface the following paragraph describes the input and output data available at the DeviceNet interface. In all cases a parameter is called ‘input signal’ when data is sent from actuator to bus, vice-versa it is called ‘output signal’...
  • Page 10 Keystone OM11 - EPI2 DEvIcENEt INtErfacE InstallatIon and maIntenance InstructIons Indication description data type range e.u. fully open the fully Open indication is set to 1 when the actuator is at fully Open position. this indication Boolean reflects the status of the open limit on the actuator.
  • Page 11: Positioning Algorithm

    Keystone OM11 - EPI2 DEvIcENEt INtErfacE InstallatIon and maIntenance InstructIons 8.2.1 Positioning algorithm a positioning algorithm (position closed loop control) is implemented on the DeviceNet interface module. the positioning function consists of comparing the position, received from the base card, with the position request received from bus. If the difference between ‘position request and present position’...
  • Page 12: Configuration Data

    Keystone OM11 - EPI2 DEvIcENEt INtErfacE InstallatIon and maIntenance InstructIons 8.6 configuration data the configuration data is received from the base card via the internal data bus and is reported to the DeviceNet network. the configuration data can also be modified via the DeviceNet network and the interface will send the new values to the logic board.
  • Page 13: Local Settings

    Keystone OM11 - EPI2 DEvIcENEt INtErfacE InstallatIon and maIntenance InstructIons When the DeviceNet Interface tries to set opening/closing speeds, When the DeviceNet Interface tries to set opening/closing torque, actuator logic sets values in function of following table: actuator logic sets values in function of following table:...
  • Page 14: Devicenet Macid Setting

    Keystone OM11 - EPI2 DEvIcENEt INtErfacE InstallatIon and maIntenance InstructIons 9.2 devicenet MacId configuration software configuration the DeviceNet interface module allows MacID If the switches specify any other invalid setting both for manual configuration as for DeviceNet Data rate, i.e. a value from 4 to 9,...
  • Page 15: Optional Kits

    Keystone OM11 - EPI2 DEvIcENEt INtErfacE InstallatIon and maIntenance InstructIons 12 optIonal KIts fIgUrE 19 the OM11 kit consists of the following parts (see figure below): - OM11 DeviceNet Interface module - 3 pcs metal spacers - 1 pc metal hexagonal spacer 15 mm...

Table of Contents