Instructions For The Installer - Smeg APL2640TC Instructions For Installation And Use Manual

Smeg range instructions for installation and use
Table of Contents

Advertisement

For operation on 380-415 V 3N
cable (5 x 1,5 mm
For operation on 380-415 V 2N
cable (4 x 2,5 mm
For operation on 220-240 V 3
cable (4 x 2,5 mm
For operation on 220-240 V
cable. (3 x 4 mm
The cable end to be connected to the appliance must be provided with
an earth wire (yellow-green) at least 20 mm longer.
READ THE CONNECTION LAYOUT PLATE UNDERNEATH THE APPLIANCE WITH CARE.
If the appliance you have purchased is not fitted with a mains power lead a power lead
resistant to a temperature of at least 90°C must be used.
Otherwise, the electrical safety of the appliance may be put at risk.
The manufacturer declines all responsibility for damage to persons or things caused by non-
observance of the above prescriptions or by interference with any part of the appliance.
Warning: pass the power cable through hole "A" and fit
the cable clamp plate after making the electrical
connection.
To fit the plate, simply use the provided bolts to secure it
under the casing as shown in the figure.
Warning: close the cable clamp after making the
electrical connection. Close the terminal board cover by
twisting it down.
30

Instructions for the installer

: use an - H05V2V2-F type five-core
2
).
: use an - H05V2V2-F type four-core
2
).
: use an - H05V2V2-F type four-core
2
).
: use an - H05V2V2-F type three-core
2
: hob with 5 cooking zones)
TYPE 1 TERMINAL BOARD
TYPE 2 TERMINAL BOARD