Caroma Invisi Series II Manual

Caroma Invisi Series II Manual

Walvit + cube 1.28/0.8 gal (4.8/3 litre) concealed tank 237060 + 237061
Hide thumbs Also See for Invisi Series II:

Advertisement

SERIES II WALVIT + CUBE
1.28/0.8 Gal (4.8/3 Litre)
1.28/0.8 Gal (4.8/3 Litre)
Concealed Tank
concealed cistern
237060, 237061 & 237062
237061 + 237062

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Invisi Series II and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Caroma Invisi Series II

  • Page 1 SERIES II WALVIT + CUBE 1.28/0.8 Gal (4.8/3 Litre) 1.28/0.8 Gal (4.8/3 Litre) Concealed Tank concealed cistern 237060, 237061 & 237062 237061 + 237062...
  • Page 2: Table Of Contents

    INVISI ™ SERIES II Contents 5 Step Easy Install ....................3 Installation Requirements ..................3 Tank Service Access Options ................4 Button Service Access Options ................5 Installing the Tank - 237 061 Inwall Access ....................6 Induct Access ....................8 Where adjustment of the tank height is required ..........
  • Page 3: Step Easy Install

    INVISI ™ SERIES II 5 Step Easy Install Check Select Select Installing Preparation Installation Tank Service Button Service the Tank for Fitout Requirements Access Options Access Options Installation Requirements 237 060 - Invisi II 4.8/3L Dual Flush Tank CONTENTS REQUIREMENTS • Invisi II - 4.8/3L Concealed Tank • 3.5"/90mm Min. Inwall Cavity Depth • Mounting Brackets...
  • Page 4: Tank Service Access Options

    INVISI ™ SERIES II Tank Service Access Options Inwall Access This allows access to tank internals through the button panel window. Standard installation requires no change to product configuration. An optional Remote Mounting Box Kit (refer to page 11) is required if using Remote Button Panel and/or extending the flush pipe . Induct Access This allows access to the whole tank. Standard installation will require Remote Mounting Box Kit (refer to page 11) for use with Remote Button Panel. Under Counter Access This allows access to tank internals through the button panel window. Standard installation requires no change to product configuration. Optional Top Access will require the access panel to be converted (refer to page 11).
  • Page 5: Button Service Access Options

    INVISI ™ SERIES II Button Service Access Options Direct Panel Mounting - Front Direct Panel Mounting - Top This is suitable for use with any of the This is suitable for use with any of the button panel kits. button panel kits. Requires a 0.2" (5mm) minimum - Requires a 0.2"(5mm) minimum - 1.8" (45mm) maximum wall thickness. 1.8" (45mm) maximum wall thickness. Access to the tank internals is Access to the tank internals is provided through the panel window. provided through the panel window.
  • Page 6: Installing The Tank - 237 061

    ADA seat height Finished Floor Level Soil Pipe Accurate positioning of the soil pipe Caroma Invisi II Integrated relative to studwork is essential. Wall Hung Bowl Bracket To achieve a minimum wall cavity of 3.5" or 90mm Use Hole #1 for Walvit Bowl 7 7/8 CL the soil pipe must be accurately centred.
  • Page 7 INVISI ™ SERIES II 237 061 Installing the Tank - Inwall Access - continued Check that the 4" (100mm) soil pipe is Move Bowl Bracket & Tank Assembly centred between the studs - check there out of its installation position and drill the 4 is 15.75" - 16.5" (400 - 420 mm) between holes in the floor as marked. Carrier must the studs (17.7" or 450mm nominal to be anchored securely to the floor. stud centres). For Structural Flooring (concrete) Drill Ø0.5" or 12mm hole for use with M12 Calculate the finished floor height TRU Bolts supplied in pack.
  • Page 8: Induct Access

    Height to WP support centre of the & flange nut selected bowl's assembl y, use Caroma Invisi II Integrated waste outlet as required Wall Hung Bowl Bracket Finished Floor Level 6.7" (170mm) Max. from finished wall with the Accurate positioning of the soil pipe...
  • Page 9: Where Adjustment Of The Tank Height Is Required

    INVISI ™ SERIES II 237 061 Installing the Tank - Where removal of the tank may be required. Where adjustment of the tank height is required. Locator Metal Arm Remove tank from Bowl Bracket using If the Height of the tank is to be lowered, Lubricate ‘O’ Ring on tank tail using soapy a screw driver to lever the plastic tab out cut the Flush Pipe and chamfer the water & slide Flush Pipe on.
  • Page 10: Installing The Tank - 237 062

    INVISI ™ SERIES II 237 062 Installing the Tank - Under Counter Access Refer to pages 6 to 7 for installation procedure. Access box converted to top (refer to page 11) Access box converted to top (refer to page 12) 15.75" - 16.5" Finished wall (400mm - 420mm) 1.8" Top Mount Button (45mm) 1.8" (45mm) –...
  • Page 11: Optional Remote Mounting Box Kit - 237 006

    INVISI ™ SERIES II 237 006 Remote Mounting Box Kit - NOTE: Recommended for ADA installations where buttons are wanted on the accessible side of the bowl. 237 006 Remote Mounting Box Kit - Kit Includes • Remote Mounting Box Remote Mounting Box • 2 x 4m Pneumatic Tubes 0.2" or 5mm min. • Elevated Flush Pipe Parts to 1.8" or 45mm max. Wall lining thickness The Remote Mounting Box has been specifically designed in conjunction with and to facilitate...
  • Page 12: Preparation For Fitout

    Mounting Box. When finishing the wall clad and tile right up to the edge of the Access Window and or Remote Mounting Box. Remote Button Mounting Attach the tubes to the tank as shown above. Break out tab in the Top Panel or Dust Cover Panel to allow the Tubes to protrude and clip back into position. Feed Pneumatic Tubes through the framework and out through the Drilled Holes. Apply tape over end of tubes to prevent any dirt from getting inside and tuck neatly back inside holes. Options for Finishing Around the Flush Pipe Cement or fibro sheet Plywood Tile Bowl Bracket Ensure the Wall Hung Bowl Mounting Bolts, Flush Pipe and Waste Pipe are all set to the correct height and spacing to suit the selected bowl. When finishing the wall clad and tile right up to the edge of these parts. The Caroma Cube and Walvit are the only bowls currently approved to be used with the Invisi bracket For instructional videos, please visit www.caromausa.com...
  • Page 13: Removing Internal Components Through Access Window

    INVISI ™ SERIES II Removing Internal Components through Access Window - Pre Installation - With Button Panel - With Blank Access Panel Full Flush Blank Access Panel Dust Cover Panel Assembly Panel Assembly Face Plate Face Plate Ball Valve Inlet Valve Outlet Valve “squeeze”...
  • Page 14: Servicing - Outlet Valve

    Servicing - Outlet Valve Servicing Requirements • Servicing is only required in instances where outlet valve operation is found to be faulty. Troubleshooting Guide • If Outlet Valve leaks ► Inspect seal for damage and replace if necessary. • If short flushing ► Check pneumatic tubes are pushed into the bridge and buttons • If any other issues arise ► Consult a plumber or Caroma After Sales Service. Spare Parts Information • Caroma Invisi II Outlet Valve compatible Spare Part Kits are: 237 072 Containing - 1 x Complete 4.8/3L Replacement Outlet Valve 237 070 Containing - Diaphragm Seal (10 Pack) 237 070S for Single Diaphram Seal Refer to Maintenance &...
  • Page 15: Servicing - Inlet Valve

    Servicing Requirements • Inlet Valve Seal may require periodic cleaning (dependant on water quality). Procedure as defined below. Troubleshooting Guide • Inlet Valve is slow to fill OR fails to open ► Ensure tap is open. • Inlet Valve fails to close ► Clean & inspect seal as described above, replace Cap Assembly & Seal if damaged. • If any other issues arise ► Consult a plumber or Caroma After Sales Service. Spare Parts Information • Caroma Invisi II Inlet Valve compatible Spare Part Kits are: 687 171 Containing - 1 x Complete Unifill Inlet Valve - with bayonet connection 687 049 687 049 Containing - 1 x Cap Assembly Cap Assembly...
  • Page 16: Important Notices

    Important Notices Important Notices Recommended Water Supply Pressure Water Supply pressure minimum 4.35psi/30 kPa - Maximum 145psi/1000 kPa Helplines Under license from Caroma Industries Limited, Australia Manufactured by SSI Sustainable Solutions International. Los Angeles, CA + Vancouver, BC www.caromausa.com www.sustainablesolutions.com 1-800-460-7019...

Table of Contents

Save PDF