Summary of Contents for Yaohua Weighing System XK3190-C601
Page 1
XK3190-C601 WEIGHING INDICATOR (BATCHING VERSION) MANUAL PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE OPERATING Dec 2006 Specifications subject to change without prior notice...
3. LAYOUT AT FRONT AND DESCRIPTION Always contact supplier for service. 4. Parameter Setting and Calibration 1.1 Introduction XK3190-C601 weighing indicator (batching version) adopts 5. INSTRUCTION FOR OPERATION MCS-51 SCM and high speed Σ – Δ A/D conversion method with 6. OPERATION ERROR CODES max.100 times/s conversion speed.
Page 3
filter intensity; Short connect PIN 1 AND PIN 2, PIN 6 and PIN 7 when connected • With self-checking for input/output hardware to load cell with a 4-wire cable; configuration and error code display function; • With RS232 output(standard)or RS422 output CAUTION (optional),communicating with PC by continuously send mode •...
Page 4
PIN # ASSIGNMENT PIN # ASSIGNMENT A. Continuously send RS422 OUTPUT+ SCOREBOARD OUT+ Data transmitted is tare weight or net weight from the display RS422 OUTPUT- SCOREBOARD OUT- of the indicator. Each time it sends one frame data to pc, one RS422 IN- 4~20mA I- frame consists of 9 groups while the data format of one group...
Page 5
Indicator will act according to instruction from computer, please refer to following notes and table: Data is transmitted serially in binary code with baud rate 600. AD: address of indicator (example A in ASCII code 41); Data format is as listed below (one group): NN: address of memory pc wants to read/write;...
For group three, Sign bit is 1; G7~G0 is binary code; Description for each pin is as listed in above table. After From G0~G17 consists of 18 bit binary code, low prior to high. connect to stylus printer, indicator could print out weighing records, accumulation value and formula.
• Load cell connection mode: 6-wire mode, auto compensation at long distance • Display Digits: 6 x numeric bits and 1 sign bit with 0.5 inch character height plus 18 status indicators [START] key • Division: 1/2/5/10/20/50 Press this key, then indicator start working in automatic •...
Page 8
This is an input indicator. It will be on when [STOP] key is Press this key to pressed or when there is a short connect between pin 1 and pin • tare off the weight of a container when weighing display 3 of control socket as listed in below table;...
Page 9
be sure to keep this input always when working in automatic O4 INDICATOR mode and there is no required condition for charge material. This is an output indicator. It will be on when weighing indicator is at the process of slow feeding for the second material.
This is an indicator to indicate which working mode the weighing When any of the pin from 2 to 7 is short connected to pin 1, indicator is at, if it’s auto mode, then auto indicator will it just gives indicator one kind of input, corresponding input be on.
Page 11
[SET—2]: Parameter for control Item Display Parameter description Remark Hardware configuration For example: Key function description at parameter setting status as [H ABCD] A- PC connection [H 1111] followed: • [↑][↓][←][→]:Shift between digits or increase value at B- Scoreboard connection digit C- Printer connection •...
Page 12
E-AD parameter setting For example: Printing language: [FLt EF] [PL *] E- AD sampling speed [FLt 22] 0- English F- AD filter intensity 1- Chinese Auto printing: [AtP *] Address for indicator 0- No auto printing [Adr **] (1~26) 1- Auto printing Baud rate(0~4) 20mA analog...
Page 13
Cycle times Ahead value for slow feed of material [Pt 0] [r******] Delay time before charge [t0 **] Q of ok range for material 2 Refer to Delay time at fast feed finish [t******] [t1 **] Footnote2 Delay time at slow feed finish [t2 **] To print above parameter set value or 0- NO...
5.1 Turning on When indicator is powered on, it will display 0~9, then it comes to weighing status. If the unloaded scale divates from zero Item Display Parameter description Remark point but still within auto zero range, then indicator will Decimal point(0~3) Press[ENTER] [dC *]...
Press [START] key or short connect Pin 1 and Pin 2 as listed above, indicator will enter into automatic control status; 5.7 Input/Output hardware check press [STOP] key or short connect Pin 1 and Pin 3 as listed At inner code display status, user can check whether the above, indicator will exit automatic control status;...
Page 16
gross weight PC send To start 02 AD 47 XH XL 03 02 41 47 30 36 03 02 AD 42 ** ** ** 02 41 42 2B 30 30 Indicator 02 AD 47 XH XL 03 02 41 47 30 36 03 Indicator Send gross start...
Page 17
02 AD 4C XH XL 03 02 41 4C 30 44 03 Print 02 AD 50 XH XL 03 02 41 50 31 31 03 PC send Indicator accumulate calibratio send n rate Indicator 02 AD 4C XH XL 03 02 41 4C 30 44 03 Accumulate send...
Page 18
accumulati on value To clear 02 AD 56 XH XL 03 02 41 56 31 37 03 Send PC send accumulati 02 AD 53 NN C1 C2 C3 02 41 53 30 30 30 Indicator accumulati on value XH XL 03 30 31 32 03 send on value...
Need help?
Do you have a question about the XK3190-C601 and is the answer not in the manual?