Chapter 1 Main Specification ◆Model: A7 ◆Accuracy Grade: Ⅲ Class ◆A/D converting theory and sampling rate: double integration, 10-15 times/time ◆Maximum inner codes: 500000 codes/time ◆Non-linearity: ≤0.01% F.S. ◆Stimulating voltage for the loadcell: DC +8V, the maximum input signal is about 16 mV ◆Loadcell quantity: 1 load cell, 4 pins, (no long distance compensation) ◆Temperature coefficient on F.S: ≤8 PPM/C ◆Display: 6-bit LED, 0.56 inches in height, 6 status indicating lights, 3 battery charges...
Chapter 2 Installation 2.1 Front and back view of the indicator Front View of the Indicator Battery start button Repair-proof Battery Ship-like Switch ( 12V / 2.2AH) Calibration Switch Power Socket Fuse Loadcell Socket Back View of the Ibdicator...
2.2 Connecting loadcell to indicator Please connects the line as following graphs End of Display End of Load-cell Shield Excitation Power Supply + Excitation Power Supply - Signal Input+ -IN +IN Signal Output- Shield Connection of the load cell ◆You must cut off the power when connecting the loadcell, and the connection must be reliable. ◆After connecting the loadcell, you should fasten the plug with screw-driver.
Chapter 3 Calibration and Adjustment 3.1 Turning on the power, and connecting the loadcell correctly, the indicator will perform self-checking, then turns into working mode (After turning on the indicator for more than 10 minutes, you can make the calibration). 3.2 Turning on the calibration switch on the back of the indicator, the indicator will go into the calibration mode, and display [n,****](**** is the previously set number), then you can set the calibration coefficients.
Page 7
will go to the next step. If you need not to change it, you can push [ C ] key to go to the next step. Step 9: Selecting manual zero-setting range: displaying [05 .**] Push [CH] key, .** will be 0.02, 0.04, 0.08, 1.00: representing respectively 2%, 4%, 8%, 100% F.S.
Page 8
1, 2, 5, 10, 20, 50 optional by pushing [CH]. For example: 5 Pushing[Tare] [E 5] pushing [Tare] to confirm, then it will return to next step. If this number needs not to be changed, pushing [C ] Will get into next step. Pushing [CH] [d 0.0] Selecting the decimal position:...
Page 9
pushing [C ] Will get into next step. Pushing [CH] [03 *.*] Choosing zero setting rate: 0.1, 0.2, 0.3 optional by pushing [CH]: meaning respectively the zero setting rate is 0.1e, 0.2e, Pushing[Tare] [03 0.3] 0.3e. Choosing one of them, pushing [Tare] to confirm, then it will return to next step.
Page 10
pushing [C ] Will get into next step. Pushing[Tare] [CAL ] Deciding the zero position: Displaying [CAL] for 2 seconds, then it will [no Load] display [no load] automatically, checking if the scale is empty,waiting for about 10 seconds till the scale returning to zero stably, pushing [Tare] to confirm, then you can go to the next step.
Chapter 5 Error Indication loaded weight is over F.S. ------------- inputing A/D number exceeds maximum number.Checking the loadcell Err 03 capacity and connection. Err 05 inputing A/D number is too small, checking the loadcell connection. loaded weight at calibration process is too small ( not near the F.S). Err 08 accumulated weight >...
Chapter 7 Maintenance 7.1 To guarantee indicator clarity and using life, the indicator shouldn’t be placed directly under sunshine and should be set in the plain space. 7.2 The indicator can’t be placed into the place where the dust pollution and vibration are serious.