M-system R3-PD16B Instruction Manual

One-shot pulse output module (triac output, 16 points)

Advertisement

Quick Links

INSTRUCTION MANUAL
ONE-SHOT PULSE OUTPUT MODULE
(triac output, 16 points)

BEFORE USE ....

Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
One-shot pulse output module ...........................................(1)
■ MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
MODEL
POINTS OF CAUTION
■ HOT INSERTION/REMOVAL OF MODULES
• Removing or replacing modules does not affect other mod-
ules on the same backplane. It is possible to replace them
without removing the power supply. However, replacing
multiple modules at once may greatly change line voltage
levels. We recommend that you replace them one by one.
• In order to prevent the erroneous output at the hot inser-
tion/removal when ON/OFF control output is in one-shot
output mode, the first data received after the hot inser-
tion/removal is used as initial value. For the combina-
tion with non-cyclic Modbus communication modules (R3-
NM1, R3-NE1, etc.) write the output data immediately
before the hot insertion/removal.
■ ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■ WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■ AND ....
• The triacs for output may be damaged, if output load is
shorted when using. Install a fuse for each output ter-
minals.
INSTALLATION
Use the Installation Base (model: R3-BSx).
R3-PD16B
EM-8390 Rev.2 P. 1 / 10

Advertisement

Table of Contents
loading

Summary of Contents for M-system R3-PD16B

  • Page 1: Before Use

    (triac output, 16 points) BEFORE USE ..POINTS OF CAUTION Thank you for choosing M-System. Before use, please check ■ HOT INSERTION/REMOVAL OF MODULES contents of the package you received as outlined below. • Removing or replacing modules does not affect other mod- If you have any problems or questions with the product, ules on the same backplane.
  • Page 2: Component Identification

    Note 1: R3-NL1 and R3-NL2 are not available with this model. SW3-4 OFF (*) Note 2: Be sure to set unused SW2-1 through 2-6 to OFF. EM-8390 Rev.2 P. 2 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 3 ON time will be as indicated below. OUTPUT ON TIME (sec.) 0.1 (*) 25.5 25.6 SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 EM-8390 Rev.2 P. 3 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 4 (11) Ch2 One Shot Output Completion Di 2 (Ch2 Output Completion Status) Note: During one shot output is on, rising edge and sinking edge are not detected. EM-8390 Rev.2 P. 4 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 5: Continuous Output Mode

    Example of Ch1 is shown below. Example of I/O Mode is in Output Operation. (SW2-7: OFF) Do 1 Di 1 (Ch1 Output Completion Status) EM-8390 Rev.2 P. 5 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 6 Ch15 Output Completion Status Do 15 Ch15 Output Completion Reset Ch16 Output Di 16 Ch16 Output Completion Status Do 16 Ch16 Output Completion Reset EM-8390 Rev.2 P. 6 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 7 Ch2 Output Di 2 Ch2 Output Completion Status Do 1 Do 2 Ch1 Output Di 1 Ch1 Output Completion Status Output Data Reset EM-8390 Rev.2 P. 7 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 8 Ch14 Output Completion Status Do 15 Ch15 Output Di 15 Ch15 Output Completion Status Do 16 Ch16 Output Di 16 Ch16 Output Completion Status EM-8390 Rev.2 P. 8 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 9: Data Assignment

    Di 2 Di 3 Di 16 Note: Di data is not practical discrete input data. It is “output completion status” internal data. EM-8390 Rev.2 P. 9 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 10: Terminal Connections

    At the startup, it outputs OFF until the communication is established and normal data is received. EM-8390 Rev.2 P. 10 / 10 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...

Table of Contents