Performance
E4 1 1/4" Clamped Pump
ELASTOMERIC AND TPE FITTED
Flow Rate
Adjustable to . . . . . . . . 0-71 gpm (268 lpm)
Port Size
Suction . . . . . . . . . . . . . . . . . . . . 1 1/2" NPT
Discharge. . . . . . . . . . . . . . . . . . 1 1/4" NPT
Air Inlet . . . . . . . . . . . . . . . . . . . . . . 1/2" NPT
Air Exhaust . . . . . . . . . . . . . . . . . . 3/4" NPT
Suction Lift
Dry . . . . . . . . . . . . . . . . . . . . . . . .19' (5.8 m)
Wet. . . . . . . . . . . . . . . . . . . . . . . .31' (9.4 m)
Max Solid Size (Diameter)
. . . . . . . . . . . . . . . . . . . . . . 3/16" (4.76 mm)
Max Noise Level . . . . . . . . . . . . 101 dB(A)
Shipping Weights
Aluminum . . . . . . . . . . . . . . . . 55 lbs (25 kg)
Cast Iron. . . . . . . . . . . . . . . . . 95 lbs (43 kg)
Stainless Steel . . . . . . . . . . . . 92 lbs (42 kg)
E4 1 1/4" Clamped Pump
PTFE Fitted
Flow Rate
Adjustable to . . . . . . . 0-64 gpm (242.3 lpm)
Port Size
Suction . . . . . . . . . . . . . . . . . . . . 1 1/2" NPT
Discharge. . . . . . . . . . . . . . . . . . 1 1/4" NPT
Air Inlet . . . . . . . . . . . . . . . . . . . . . . 1/2" NPT
Air Exhaust . . . . . . . . . . . . . . . . . . 3/4" NPT
Suction Lift
Dry . . . . . . . . . . . . . . . . . . . . . . . .12' (3.7 m)
Wet. . . . . . . . . . . . . . . . . . . . . . . .29' (8.8 m)
Max Solid Size (Diameter)
. . . . . . . . . . . . . . . . . . . . . . 3/16" (4.76 mm)
Max Noise Level . . . . . . . . . . . . . 98 dB(A)
Shipping Weights
Aluminum . . . . . . . . . . . . . . . . 55 lbs (25 kg)
Cast Iron. . . . . . . . . . . . . . . . . 95 lbs (43 kg)
Stainless Steel . . . . . . . . . . . . 92 lbs (42 kg)
3
• Model E4 Metallic Clamped
10
320
140
5
10
90
9
280
120
80
8
240
70
7
100
200
60
6
80
50
5
160
60
40
4
120
30
3
40
80
20
2
20
40
10
1
0
0
0
0
0
Meters
Feet
BAR
0
NOTE: Performance based on the following: elastomeric fitted pump, flooded suction, water at
ambient conditions. The use of other materials and varying hydraulic conditions may result in
deviations in excess of 5%.
10
320
140
10
90
9
20
30
280
120
80
8
240
70
7
100
200
60
6
80
50
5
160
60
40
4
120
30
3
40
80
20
2
20
40
10
1
0
0
0
0
0
Meters
Feet
BAR
0
NOTE: Performance based on the following: PTFE fitted pump, flooded suction, water at ambient
conditions. The use of other materials and varying hydraulic conditions may result in deviations in
excess of 5%.
Displacement Per Stroke, 0.25 Gal. (0.95 L)
20
30
40
50
10
20
30
40
Capacity in U.S. Gallons Per Minute
50
100
150
Capacity in Liters Per Minute
Displacement Per Stroke, 0.13 Gal. (0.49 L)
40
50
60
10
20
30
Capacity in U.S. Gallons Per Minute
50
100
Capacity in Liters Per Minute
.
www
versamatic
AIR CONSUMPTION IN SCFM
AIR PRESSURE IN PSI
SCFM M 3 /HR
5
8.5
10
17
20
34
60
30
51
40
68
50
85
60
101.9
50
60
70
200
250
AIR CONSUMPTION IN SCFM
AIR PRESSURE IN PSI
SCFM M 3 /HR
10
17
20
34
30
51
40
68
50
85
60
101.9
40
50
60
150
200
250
.
com
e4mdlAsmC-rev1213