2. USB Transducer GP 5.0 MHz / AB 5.0 MHz:
This device is a hand-held, single element, mechanical sector probe intended for transcutaneous use
with the INTERSON USB ULTRASOUND PROBE SYSTEM. The nominal operating frequency is 5.0
MHz. In B-mode, the transducer operates over a 32 mm area as an end-firing probe. This device is
intended for use with the INTERSON USB ULTRASOUND PROBE SYSTEM for the transcutaneous
imaging of neonatal, abdominal organs and structures including the gastrointestinal tract, kidney,
bladder, etc., to aid in the detection and assessment of physical and functional abnormalities using
established diagnostic criteria.
3. USB Transducer SP 7.5 MHz / PI 7.5 MHz:
This device is a hand-held, single element, mechanical sector probe intended for transcutaneous use
with the INTERSON USB ULTRASOUND PROBE SYSTEM. The nominal operating frequency is 7.5
MHz. In B-mode the transducer operates over a 20 mm area as an end-firing probe. This device is
intended for use with the INTERSON USB ULTRASOUND PROBE SYSTEM for the transcutaneous
imaging of neonatal, abdominal organs and structures including the gastrointestinal tract, kidney,
bladder, etc., peripheral vessels, and small organs to aid in the detection and assessment of physical
and functional abnormalities using established diagnostic criteria.
5. USB Transducer MV 12.0 MHz / NV 12.0 MHz:
This device is a hand-held, single element, mechanical sector probe intended for transcutaneous use
with the INTERSON USB ULTRASOUND PROBE SYSTEM. The nominal operating frequency is 12
MHz. In B-mode the transducer operates over a 29 mm area as an end-firing probe. This device is
intended for use with the INTERSON USB ULTRASOUND PROBE SYSTEM for the transcutaneous
imaging of peripheral vessels and as small organs to aid in the detection and assessment of physical
and functional abnormalities using established diagnostic criteria.
6. USB Transducer SR 7.5 MHz / VA 7.5 MHz:
This device is a hand-held, single element, mechanical sector probe intended for transcutaneous use
with the INTERSON USB ULTRASOUND PROBE SYSTEM. The nominal operating frequency is 7.5
MHz. In B-mode the transducer operates over a 29 mm area as an end-firing probe. This device is
intended for use with the INTERSON USB ULTRASOUND PROBE SYSTEM for the transcutaneous
imaging of peripheral vessels and small organs to aid in the detection and assessment of physical and
functional abnormalities using established diagnostic criteria.
7. USB Transducer EC 7.5 MHz / EB 7.5 MHz:
This device is a hand-held, single element, mechanical sector probe intended for transcutaneous use
with the INTERSON USB ULTRASOUND PROBE SYSTEM. The nominal operating frequency is 7.5
MHz. In B-mode the transducer operates over a 21 mm area as a side-firing probe. This device is
intended for use with the INTERSON USB ULTRASOUND PROBE SYSTEM for the transcutaneous
imaging of endocavity, etc. and small organs to aid in the detection and assessment of physical and
functional abnormalities using established diagnostic criteria.
01-9932-00 ViewBladder 10 User Guide Revision 2