DISASSEMBLY/ASSEMBLY PROCEDURES

9.3 Slide the PCB clear of the connector
panel, and pull it away from the base.
9.4 Remove any connections required to
troubleshoot the PCB.
10. Audio PCB Replacement
Note: Make sure that the connections to
the Headphone Jack PCB (10) are routed
through the guiding notch on the side of the
console (see Figure 7).
10.1 Restore any connections that were
disconnected during troubleshooting.
10.2 Slide the PCB's connectors through
the holes in the rear of the base (19).
10.3 Snap the PCB (10) carefully down
under the four locking tabs. Make sure that
the CD mechanism connections are routed
properly. See Figure 7 and procedure 6
note.
10.4 Replace the Digital PCB (Procedure
8), the door/right cover assembly (Proce-
dure 4), and the left cover assembly (Pro-
cedure 2).
11. Headphone Jack PCB Removal
Note: Refer to Figures 3 and 7 for Proce-
dures 11 and 12.
11.1 Remove the left cover assembly
(Procedure 1) and door/right cover assem-
bly (Procedure 3).
11.2 There are two black plastic snaps that
secure the PCB (10). Flex the snaps
outward and carefully pull the PCB away
from the unit.
12. Headphone Jack PCB Replacement
12.1 Snap the PCB (10) into place by
engaging the two locking tabs.
Note: Make sure that the connector wires
are routed through the guiding notch on the
side of the base (19).
12.2 Replace the door/right cover assembly
(Procedure 4) and the left cover assembly
(Procedure 2).