6Es5 242 Module Memory Map; Module Pin Out - Siemens 6ES5-424 Technical Reference Manual

Counter module
Table of Contents

Advertisement

Chapter 2
Module Setup Procedures
2.9
Module Pin Out
The 6ES5 242 module is supplied with a 48-pin connector
which conforms to DIN 41612. The pin out of the module is
listed below.
Pin
d
b
z
2
0
v
+5
v
4
PESP
6
ADB 0
CPKL
8
ADB 1
MEMR'
10
ADB 2
MEMW'
12
ADB 3
RDY'
IRA'
ADB 4
IRB'
ADB 5
IRC'
ADB 6
IRD'
ADB 7
IRE'
ADB 8
IRF
ADB 9
.IRG'
ADB 10
ADB 11
DB 0
DB 1
DB 2
DB 3
DB 4
DB 5
DB 6
DB 7
PL 4, EANK'
2.1 0 6ES5 242 Module Memory Map
Setting of the physical address of the 6ES5-242 module was
discussed in an earlier section. In that section the subaddress
was shown to have 16 possible addresses. This section will
map out these 16 subaddresses.
Direct reading and writing operations to the module are
accomplished through peripheral words (PWxx). This is
particulary useful when you need to develop a "custom"
software function. See Chapter 4 for detailed information on
Standard Software Blocks. Exercise extreme caution when
using this feature with standard software, as these two opera-
tions may interfere with each other.
Sub
Register name
Address Write Operation
xxxO
Control
xxxl
not assigned
xxx2
Function Number
xxx3
not assigned
xxx4
lnterrupt Mask
-
High*
xxx5
lnterrupt Mask
-
Low*
m 6
Master Mode
-
High*
xxx7
Master Mode
-
Low*
xxx8
Counter Mode
-
High*
xxx9
Counter Mode
-
Low*
xxxA
Load -High*
xxxB
Load -Low*
xxxC
Hold
-
High*
xxxD
Hold -Low*
xxxE
Alarm
-
High*
xxxF
Alarm
-
Low"
Register name
Read Operation
lnterrupt Information
-
High
lnterrupt Information
-
Low
Error Signal
-
High
Error Signal
-
Low
not assigned
not assigned
Result Counter 1
-
High
Result Counter 1
-
Low
Result Counter 2
-
High
Result Counter 2
-
Low
Result Counter 3
-
High
Result Counter 3
-
Low
Result Counter 4
-
High
Result Counter 4
-
Low
Result Counter 5
-
High
Result Counter 5
-
Low
*: The value in this register will be sent to any of the counters
specified during the parameter assignment.
NOTE:
The Standard software offering does not read the alarm
i
register when parameters are assigned to counters 3,4, and 5.