Ensure that the voltage of your electricity supply corresponds to the serial plate
details. The product is supplied with a 13 Amp plug. To replace the plug, follow
these instructions:
 green and yellow wire to 'E' or (Earth)
 blue wire to 'N' (Neutral)
 brown wire to 'L' (Live)
For safety regulations, the plug must always be accessible.
THIS APPLIANCE MUST BE EARTHED

Warning

Under no circumstances must the power supply be switched ON and OFF in
quick succession over a short period. To do this could result in serious damage
to the compressor, causing failure of refrigeration system. Having completed the
electrical connection, the cabinet can be switched 'On' at the mains. When the
unit is first switched 'ON 'you will hear condenser fan motors running and the
compressor, evaporator fan will come 'On' when the evaporator is cooled to
correct temperature. The temperature inside the cabinet is controlled by mean
of electronic controller, which is factory set and should not need any
adjustment. The cabinets are designed to be left ON at all times, like a domestic
refrigerator Ensure the door of the cabinet remain closed when not being used.
Failure to do so will reduce the efficiency of the refrigeration system and may
cause excess condensation or ice build up on the evaporator.

User Maintenance

Due to electrical regulation only a very limited amount of user maintenance
work can be carried out. There are no user serviceable parts inside the
refrigeration compartment.
Please note- No cleaning or maintenance work should be attempted until
the cabinet is switched off and the plug removed from the socket.
Only use genuine Lincat spares. All parts numbers are listed on the Spares list
on page 6 for easy ordering when required.

Defrosting

The Seal Refrigerated Merchandises are fitted with an automatic defrost
function ensuring the cooling heat exchanger remains free from ice. The
condensate water is automatically dispersed using the heat from the
refrigeration unit.

Loading

When loaded ensure that air can circulate around / through store products.
Cover all foods and separate raw and cooked food. Do not allow items to
overhang the edges of the shelves.
IS517 ECN4508