Summary of Contents for Lincat C6R/75U

  • Page 1 User and Installation Instructions Seal Refrigerated Merchandisers C6R/75U, C6R/100U, C6R/125U, C6R/105, C6R/130, D6R/75, D6R/100, D6R/125, D5R/100, D5R/125 D3R/100 IS517 ECN4508 Page 1...
  • Page 2 Used for the purposes for which it is intended, and with careful maintenance as outlined in this User Guide, your Lincat product will give years of trouble free use. IMPORTANT INFORMATION Please read all of the safety and operating instructions carefully before using this product.
  • Page 3: Table Of Contents

    CONTENTS Contents Page Safety instructions………………………………………………………4 Product specification………………………………………………….. 5 Features………………………………………………………………….. 5 Technical specification…………………………………………………5 Pack contents…………………………………………………….………6 Spare parts list………………………………………………………….. 6 Installation……………………………………………………………….. 7 Note to installer.......……………………………. 7 Inspection......…………………………….……... 7 Handling.................. 7 General............……………………7 Connecting to the electricity ......……………….7-8 Warning ............……………………8 User Maintenance ........……………………8 Defrosting ............……………………8 Warning ............……………………8...
  • Page 4: Safety Instructions

    Do not try to modify this product. Ensure that the electrical supply cable is not damaged. If the supply cable is damaged, it should be replaced by Lincat Ltd or suitably qualified persons, in order to avoid a hazard. IS517 ECN4508...
  • Page 5: Product Specification

    PRODUCT SPECIFICATION 650 Range Refrigerated Merchandiser – C6R/75, C6R/100, C6R/105, C6R/125, C6R/130 D6R/100, D6R/125 500 Range Refrigerated Merchandiser – D5R/100, D5R/125 350 Range Refrigerated Merchandiser – D3R/100 FEATURES Fan-assisted refrigeration Independently switchable light Double glazed glass (flat panels) Adjustable shelf positions (back Electronic control service models only) Hot gas automatic defrost...
  • Page 6: Pack Contents

    User Guide 2 x removable base panels Guarantee card 2 x sliding doors C6R/75U, C6R/100U, C6R/125U Drop-in Models As above, plus drop-in refrigeration module D5R/100, D5R/125, D3R/100 Models As above, except 1 x chrome plated shelf and removable base plate.
  • Page 7: Installation

    INSTALLATION All models (For C6R/75U,C6R/100U,C6R/125U Models see additional instructions) Note to installer Please follow this instruction carefully. Only if the cabinet is correctly installed will it give the best possible performance and reliability. Please pay particular attention to the User maintenance section of this guide that the controller must be left on the factory setting.
  • Page 8: Warning

    Please note- No cleaning or maintenance work should be attempted until the cabinet is switched off and the plug removed from the socket. Only use genuine Lincat spares. All parts numbers are listed on the Spares list on page 6 for easy ordering when required.
  • Page 9 INSTALLATION INSTRUCTIONS FOR C6R/75U, C6R/100U, C6R/125U DROP-IN MODELS Refer to the information on page 4 before proceeding. The cabinet is not connected to the refrigeration module during transit. Remove the doors, shelves and base panels from the cabinet and lift this from the pallet first to separate the two parts of the appliance.
  • Page 10: Details Of Cut-Out For Refrigeration Module

    Details of the base section and cabinet (1) Details of cut-out for refrigeration module (2) BACK OF COUNTER / FOOD SERVICE SIDE FRONT OF COUNTER / CUSTOMER SIDE 750 Models 750 Models 1000 Models 1000 1250 Models 1250 IS517 ECN4508 Page 10...
  • Page 11 Ventilation requirements for drop in models Fig 1 It is crucial for the operation of the refrigeration system that a free flow of air is maintained around condensing unit. The ideal method is to site the cabinet within a counter where the back is completely open as Fig 1.
  • Page 12: Ventilation Requirement For Counter Top Models

    Ventilation requirements for counter top models Minimum distance of vents from any adjacent wall or surface 500mm D6R/75B & S 200mm D6R/100B & S D6R/125B & S 500mm C6R/105BL & BR 200mm C6R/105SL & SR C6R/130BL & BR C6R/130SL & SR 500mm D5R/100B &...
  • Page 13 WIRING DIAGRAM C6R75-100-125-U LIGHT EVAPORATOR EVAPORATOR CONDENSER COMPRESSOR HOT GAS SOLONOID FRAME HEATER FRAME HEATER 11 10 CONTROLLER LIGHT MAIN SWITCH SW ITCH IS517 ECN4508 Page 13...
  • Page 14 WIRING DIAGRAM C6R105-130-D5R & D3R LIGHT NOTE: ONE CONDENSER FITTED ON C6R105,D3 &D5 MODELS TWO CONDENSER FITTED CONDENSER ON C6R130 MODELS HOT GAS COMPRESSOR SOLONOID EVAPORATOR EVAPORATOR CONDENSER FRAME HEATER CONNECTOR FRAME HEATER NOTE: ONE CH11 FRAME HEATER CONTROLLER FITTED ON D3R & D5R MODELS MAIN LIGHT SW ITCH...
  • Page 15 WIRING DIAGRAM D6R75-100-125 LIGHT COMPRESSOR EVAPORATOR EVAPORATOR C A B IN E T P R O B E S U CT IO N P RO B E DEFROST SOLONOID 12 11 10 9 8 7 3 2 1 CONTROLLER 2 FAN CONDENSER 1 FAN FOR D6R100 &...
  • Page 16: Troubleshooting

    Troubleshooting Problem Possible Cause Solution Compressor will not start No voltage in socket Use voltmeter to check Electrical conductor or wires may be Use ohmmeter to check for continuity Defective electrical component: Replace defective component controller, relay, thermal protector etc Measure ohmic resistance of main Compressor motor has a winding and auxiliary winding using...
  • Page 17 Find the location of gas leak in order The refrigerant gas is leaking to seal and replace the defective component. Change the drier. Perform a good vacuum and recharge unit. Find the location of gas leak in order The refrigerant gas is leaking to seal and replace the defective component.
  • Page 18: Operating Instructions

    OPERATING INSTRUCTIONS 1. On/Off Switch 2. Light Switch 3. Temperature Control The control panel layout may vary. Ensure shelves are secure. Close the doors. To check operation of the unit, connect it to the electricity supply, switch on the light (2) and the light will illuminate, and then switch on the refrigeration using the On/Off switch (1), the temperature controller will illuminate and the cabinet will begin to cool.
  • Page 19: Cleaning And Maintenance

    CLEANING AND MAINTENANCE CLEANING Disconnect the unit from the electricity supply. Use a mild detergent in hot water and a soft cloth. Do not use abrasive creams or scourers. Remove the rear doors, shelves and base panels. Shelves (including supports) and base-panels may be washed in a dishwasher. MAINTENANCE Regular cleaning of the unit is recommended.
  • Page 20: Service Information

    All available on serial plate Type number  Serial number Lincat reserve the right to carry out any work under warranty, given reasonable access to the appliance, during normal working hours, Monday to Friday, 08:30 to 17:00. GUARANTEE This unit carries a comprehensive UK mainland twelve month / 2 year warranty.