3. ADAPTATION TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, disconnect the
appliance from the mains.
The hob of the cooker is adjusted for use with either natural gas at a
pressure of 1.0kPa (FS61XNG-FS62XNG-FS60WHNG-FS60XNG) or
LPG (propane) at a pressure of 2.75 kPa (FS61XLPG-FS62XLPG). If
used with other types of gas, you have to replace the nozzles, then
adjust the minimum flame on the gas taps. For nozzle replacement and
burner adjustment operate as described in the following paragraph.
3.1 Replacement of nozzles on the hob
This operation requires no primary air regulation.
1.
2.
3.
4.
10
Instructions for the installer
Extract the grids and remove all the caps and flame-spreader
crowns;
unscrew the burner nozzles with a 7 mm socket wrench;
replace the nozzles according to the type of gas to be used and the
description in paragraph "3.2 Burner and nozzle characteristics
table".
Replace the burners in the correct position.