5.2 Regulation for LPG

Loosen screw A and push support B all the way. Use a double head
wrench to remove nozzle C and assemble the suitable one, following the
instructions indicated in the reference charts, with respect to the type of
gas to use. The screwing torque of the nozzle should never exceed
3 Nm. Reposition support B so that nozzle C is covered perfectly.
Move the Venturi tube D to regulate the air flow until distance "X" is
reached indicated in the chart in paragraph "5.4 Regulation of primary air"
and then secure the tube by means of screw A. After the regulations
have been carried out, restore the seals with sealing wax or equivalent
material.
Burner
Auxiliary (1)
Triple crown (2)
Double crown
internal (3)
external (3)
(*) By-pass value for valveless appliances.
26
Instructions for the installer
Rated
heating
capacity
(kW)
Nozzle
diameter
1/100 mm
1.05
3.3
0.8
3.3
LPG – G30/G31 28/37 mbar
By-pass
mm
1/100
48
30
33 (*)
87
55
42
26
33 (*)
87
55
Reduced
Flowrate
flowrate
g/h G30
(W)
380
76
1200
240
380
58
1200
240
Flowrate
g/h G31
75
236
57
236

Advertisement