Johnson Controls Unitary Products PHE4 Series Installation Manual

Single package heat pump/electric 2-5 ton

Advertisement

INSTALLATION MANUAL
SINGLE PACKAGE
HEAT PUMP/ELECTRIC
MODELS: PHE4 Series
(2-5 Ton)
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
MODEL NUMBER NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
AIRFLOW PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Component Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Unit 4 Point Load Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Bottom Duct Dimensions (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Rear Duct Dimensions (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Typical Field Power Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . 7
Unit Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Weights and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Unit Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Single Point Connection Kit Required . . . . . . . . . . . . . . . . . . . . . . . . 8
Electrical Data for 208-1-60 Multi Source Power . . . . . . . . . . . . . . . . 9
Electrical Data for 230-1-60 Multi Source Power . . . . . . . . . . . . . . . 10
Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
SECTION I: GENERAL INFORMATION
PHE units are factory assembled heat pumps designed for outdoor
installation on a roof top or a slab. Field-installed optional electric heater
accessories are available to provide supplemental electric heat com-
bined with electric cooling and heating.
The units are completely assembled on rigid, removable base rails. All
piping, refrigerant charge, and electrical wiring is factory installed and
tested. The units require only electric power condensate drain and duct
connections at the point of installation.
SECTION II: SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury.
Johnson Controls Unitary Products
LIST OF SECTIONS
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
TYPICAL WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
START UP SHEET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
LIST OF FIGURES
Single Point Wiring Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Demand Defrost Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Measuring External Static Pressure . . . . . . . . . . . . . . . . . . . . . . . . . 18
Connection Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Ladder Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
R-410A Quick Reference Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
LIST OF TABLES
Airflow - Side Duct Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Airflow - Bottom Duct Application . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Electric Heat Minimum Supply Air . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Electric Heat Multipliers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Additional Static Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Demand Defrost Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Test Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Fault Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Thermostat Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
CAUTION indicates a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury. It is also used to
alert against unsafe practices and hazards involving only property dam-
age.
Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service or maintenance
can cause injury or property damage. Failure to carefully read and
follow all instructions in this manual can result in furnace mal-
function, death, personal injury and/or property damage. Only a
qualified contractor, installer or service agency should install this
product.
This product must be installed in strict compliance with the installa-
tion instructions and any applicable local, state, and national codes
including, but not limited to building, electrical, and mechanical
codes.
® ®
WARNING
!
CAUTION
!
5020803-UIM-C-0715

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PHE4 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Johnson Controls Unitary Products PHE4 Series

  • Page 1: Table Of Contents

    SINGLE PACKAGE ® ® HEAT PUMP/ELECTRIC MODELS: PHE4 Series (2-5 Ton) LIST OF SECTIONS GENERAL INFORMATION ....... . 1 OPERATION .
  • Page 2: Model Number Nomenclature

    Code Part 1, C22.1 (latest editions). dures such as the Air Conditioning Contractors of America (manual J). 2. Local plumbing and waste water codes and other applicable local codes. Johnson Controls Unitary Products...
  • Page 3: Component Location

    ELECTRIC HEAT KIT INDOOR COIL INDOOR BLOWER REMOVABLE BASE RAILS A0380-001 FIGURE 1: Component Location Table 1: Unit Limitations Unit Limitations Model Unit Voltage Applied Voltage Outdoor DB Temp Max (°F) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Johnson Controls Unitary Products...
  • Page 4: Unit 4 Point Load Weight

    OF UNIT "B" A0295-001 FIGURE 2: Unit 4 Point Load Weight Table 2: Weights and Dimensions Model Weight (lbs.) Center of Gravity 4 Point Load Location (lbs.) Shipping Operating Johnson Controls Unitary Products...
  • Page 5: Unit Dimensions

    3. Units may be installed on combustible floors made from wood or class A, B or C roof covering materials. Note: For units applied with a roof curb, the minimum clearance may be reduced from 1 inch to 1/2 inch? between combustible roof curb material and this supply air duct. Johnson Controls Unitary Products...
  • Page 6: Bottom Duct Dimensions (Inches)

    Table 4. 1. Remove the duct covers found in the bottom return and supply air duct openings. There are four (4) screws securing each duct cover (save these screws to use in Step 2). Johnson Controls Unitary Products...
  • Page 7: Typical Field Control Wiring Diagram For Heat Pump Models

    UL1995, Article 26.19 (in reference to all circuit break- Refer to Figures 6 and 7 for typical field wiring and to the appropriate ers). unit wiring diagram for control circuit and power wiring information. Johnson Controls Unitary Products...
  • Page 8: Electrical Data - 208/230-1-60 - Single Source Power

    15.9 62.5 69.1 117.3 125.6 6HK16502006 14.4 17.6 69.2 76.5 125.7 134.9 1. MCA = Minimum Circuit Ampacity. 2. MOP = Maximum Over Current Protection device; must be HACR type circuit breaker or time delay fuse. Johnson Controls Unitary Products...
  • Page 9: Electrical Data For 208-1-60 Multi Source Power

    6HK16501806 13.0 62.5 34.4 52.1 26.0 6HK16502006 14.4 69.2 34.4 43.3 43.3 6HK26501306 45.2 34.4 56.5 6HK26501506 10.8 51.9 34.4 64.9 6HK26501806 13.0 62.5 34.4 78.1 6HK26502006 14.4 69.2 34.4 86.5 For notes, see Page 10. Johnson Controls Unitary Products...
  • Page 10: Electrical Data For 230-1-60 Multi Source Power

    23.9 6HK(0,1)6500806 30.9 26.4 38.6 6HK(0,1)6501006 38.3 26.4 47.8 6HK16501306 11.5 50.0 26.4 41.7 20.8 6HK16501506 13.2 57.4 26.4 47.8 23.9 6HK26501306 11.5 50.0 26.4 62.5 6HK26501506 13.2 57.4 26.4 71.7 For notes, see Page 11. Johnson Controls Unitary Products...
  • Page 11 6HK16502506 22.0 95.7 39.2 47.8 47.8 23.9 6HK26502506 22.0 95.7 39.2 119.6 1. MCA = Minimum Circuit Ampacity. 2. MOP = Maximum Over Current Protection device; must be HACR type circuit breaker or time delay fuse. Johnson Controls Unitary Products...
  • Page 12: Single Point Wiring Kits

    TO L2 on HEAT KIT BREAKER(S) NOTE: For single circuit heater kits, remove the wires for the second circuit from the single-point block. (Mount with 4 self tapping screws as shown.) A0352-003 FIGURE 8: Single Point Wiring Kits Johnson Controls Unitary Products...
  • Page 13: Physical Data

    Field-supplied external filters must be sized so as not to exceed 300 fpm air velocity through disposable fil- Quantity size ters. For internal filter use, a filter rack kit is available. Consult the instructions supplied with that kit for replacement filter sizes. Filter sizes: A=20x20, B=20x30. Johnson Controls Unitary Products...
  • Page 14: Airflow Performance

    4. Minimal variations in airflow performance data results from operating at 208 volts. Data above may be used in those cases. 5. Heating applications tested at 0.50" w.c. esp, and cooling applications tested at 0.30" w.c.esp per standards. Johnson Controls Unitary Products...
  • Page 15: Airflow - Bottom Duct Application

    Table 12: Electric Heat Multipliers 1. Electric heaters are rated at nominal voltage. Use this table to determine the electric heat capacity for heaters applied at lower voltages. Voltage kW Capacity Multipliers Nominal Applied 0.75 0.92 Johnson Controls Unitary Products...
  • Page 16: Operation

    0.25 IWG, the unit will deliver less CFM during full economizer operation. temperature is above 50°F. All defrost timing occurs only while the com- Filter pressure drop based on standard filter media tested at velocities not to exceed 300 ft/min. pressor is on. Johnson Controls Unitary Products...
  • Page 17: Demand Defrost Control

    Outdoor ambient sensor failure (Open or Shorted) 9 Flashes Table 15: Test Pins Control Failure 10 Flashes Test Pin Shorted no Y > 2 sec Bypass ASCD Show error coder > 5 sec Forced defrost Clear error codes Johnson Controls Unitary Products...
  • Page 18: Measuring External Static Pressure

    Outdoor fan instant off Y & O OFF Reversing valve de-energized Indoor blower switches to continuous fan speed * Motor program has 60 second blower off delay on all 5 speed taps. FIGURE 10: Measuring External Static Pressure Johnson Controls Unitary Products...
  • Page 19: Maintenance

    The wire number or color and terminal designations referred to may vary. Check the wiring label inside the control box access panel for the correct wiring. DO NOT use a pressure washer as coil fin damage will occur. Johnson Controls Unitary Products...
  • Page 20: Typical Wiring Diagrams

    8. BLOWER MOTOR SPEED CONNECTIONS SHOWN ARE TYPICAL, BLACK WIRES FROM THE 230 TO THE 208 VOLT TAP ON THE TRANSFORMER. BUT MAY VARY BY MODEL AND APPLICATION. 4. MOTORS ARE INHERENTLY PROTECTED. FIGURE 11: Connection Wiring Diagram Johnson Controls Unitary Products...
  • Page 21: Ladder Wiring Diagram

    8. BLOWER MOTOR SPEED CONNECTIONS SHOWN ARE TYPICAL, BLACK WIRES FROM THE 230 TO THE 208 VOLT TAP ON THE TRANSFORMER. BUT MAY VARY BY MODEL AND APPLICATION. 4. MOTORS ARE INHERENTLY PROTECTED. FIGURE 12: Ladder Wiring Diagram Johnson Controls Unitary Products...
  • Page 22: R-410A Quick Reference Guide

    Never open system to atmosphere when under a vacuum. If system must be opened for service, evacuate system then break the vacuum with dry nitrogen and replace all filter driers. FIGURE 13: R-410A Quick Reference Guide Johnson Controls Unitary Products...
  • Page 23: Start Up Sheet

    Supply air dry bulb temperature Outside air dry bulb temperature Return static (inches of water column) Return air dry bulb temperature Return air wet bulb temperature Total external static pressure Temperature drop Supply air wet bulb temperature Johnson Controls Unitary Products...
  • Page 24 Refrigerant Charge and Metering Device R-410A R-22 Suction line temperature Discharge pressure Data plate - lbs / Oz Fixed Orifice Suction pressure Liquid line temperature Discharge line temperature TXV# / Orifice size Superheat Subcooling Electric Heat (Supplemental and Emergency Heat) Electric heat kit - Model number Serial number Rated KW...

Table of Contents