Table 11. Spi Control Message (0X04 Data Format); Table 12. Spi Inertial Message (0X05 Data Format); Table 13. Spi Control Message (0X0C Data Format); Table 14. Spi Inertial Message (0X0D Data Format) - Honeywell HG1120 Installation And Interface Manual

Inertial measurement unit
Table of Contents

Advertisement

HG1120 Installation and Interface Manual

Table 11. SPI Control Message (0x04 Data Format)

POSITION
PARAMETER
0
SPI Data Size
1-14
Control Data
15-20
Spare
Total Length

Table 12. SPI Inertial Message (0x05 Data Format)

POSITION
PARAMETER
0
SPI Data Size
1-20
Control and Navigation Data
Total Length

Table 13. SPI Control Message (0x0C Data Format)

POSITION
PARAMETER
0
SPI Message Data Size
1-14
Control Data
15-20
Spare
Total Length

Table 14. SPI Inertial Message (0x0D Data Format)

POSITION
PARAMETER
0
SPI Message Data Size
1-20
Control and Navigation Data
Total Length
aerospace.honeywell.com/HG1120
|
LENGTH
LSB WEIGHT
(BYTES)
1
1
26
N/A
24
51
LENGTH
LSB WEIGHT
(BYTES)
1
1
50
N/A
51
LENGTH
LSB WEIGHT
(BYTES)
1
1
26
N/A
24
N/A
51
LENGTH
LSB WEIGHT
(BYTES)
1
1
50
N/A
51
UNITS OR CONTENTS
Number of bytes of data in message
items 1..14 = 26
See Message 0x04
Positions 1-14
None
UNITS OR CONTENTS
Number of bytes of data in message
items 1..20 = 50
See Inertial Message 0x05
Positions 1-20
UNITS OR CONTENTS
Number of bytes of data in message
items 1..14 = 26
See Control Message 0x0C
Positions 1-14
None
UNITS OR CONTENTS
Number of bytes of data in message
items 1..20 = 50
See Inertial Message 0x0D Format,
Positions 1-20