MAINTENANCE & TROUBLESHOOTING
1
What shall I do if the Nebulizer Warning Light is on?
Check the nebulizer unit to see if it is installed properly. Make sure the
nebulizer is fully seated in its socket.
2
What shall I do if the mist volume is abnormally low?
In a typical polishing cycle, the alcohol mist should fill the entire chamber within
several minutes. If, however, the mist volume is observed to be low, or not reaching
the full height, check the reservoir to see if it is running low or empty, and refill it if
necessary. Low mist volume can also be a sign to replace the nebulizer.
3
Draining the reservoir
A 30 mL pipette is provided for removing alcohol from the reservoir. Avoid any heat
source, open flames or sparks when draining the reservoir. The alcohol, unless
contaminated, can be repeatedly used for polishing.
4
Removing the casing
The Polysher
TM
is needed to fully remove the casing, follow the instructions below:
Raise the platform to the upmost position;
Lift the casing all the way up, gently flex the thin section outward and pull it off the
machine;
To put the casing back on, flex the thin section the same way and slide it through the
moving post. Make sure it seats exactly on the rubber seal of the base.
can be operated without the need to remove the casing. However, if it
16