Download Print this page

Technical Specifications - Carrier 33CSSP3-FC Installation Instructions Manual

7-day programmable 2 or 4 pipe systems fan coil thermostat
Hide thumbs Also See for 33CSSP3-FC:

Advertisement

Technical Specifications

Fan Coil Series Thermostat Controllers
XXXXX
Series Thermostat Controllers
Power Requirements
Output Rating
Digital Inputs
H2O
CK1
Local Temperature Sensor Type
Remote Temperature
Sensor Type
Wire Size
Temperature Adjustment Range
Accuracy
Deadband
Operating
Ambient
Conditions
Storage
Compliance
Dimensions
Shipping Weight
North American Emissions Compliance
United States
This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area may cause harmful interference, in which case the users
will be required to correct the interference at their own expense.
Canada
This Class (B) digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numerique de la Classe (B) respecte toutes les exigences du Reglement sur le materiel brouilleur du Canada.
20 - 30 VAC 50/60 Hz, 3 VA @ 24V nominal.
Valve Outputs 0.8A max, 0.01A min, 3A inrush, 20 - 30 VAC
Fan Outputs 0.4A max, 0.01A min, 3A inrush, 20 - 30 VAC
voltage free contacts, closed to signal CHILLED water supply
voltage free contacts, closed to alter setpoints
solid state temperature sensor, 10 mV / degF
solid state temperature sensor, digital communications over two wires,
5 ft cable supplied, accurate to 1 degF
16 AWG (100 ft max) to 24 AWG (36 ft max)
35 to 99 deg F (2 to 36 degC)
35 to 65 deg F +/- 3 degF, greater than 65 to less than 80 degF +/- 2 degF,
80 to 99 degF +/- 3 degF, greater than 99 to 104 degF +/- 5 degF
Adjustable 1 to 6 deg first stage, fixed 1 degree for med/hi fan speeds
35 to 104 degF (2 o 40 degC), 5 - 95% RH non-condensing, 86 degF
max dew point
-22 to 122 degF (-30 to 50 degC), 5-95% RH non-condensing, 86 degF
max dew point
UL/cUL listed, file E107041, NEC Class 2
3.14" H x 3.14" W x 1.1" D