Application – user program created using ALP software Display element – program element used for displaying information on the display akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
The analog inputs can be configured as analog or as digital. For further details see section 4 ‘Functioning’ Fig. 1.1 Front housing (front cover is open) akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
The design of the relay enables to increase the number of RS485 interfaces by installing up to two interface cards. Ordering code for interface card: PR-IC485 akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
4 (1-4, 5-8) Test voltage between 1780 V input groups Test voltage against 2830 V other circuits akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Page 7
* The limitation applies only to the slave mode, in which all network variables are automatically declared as retain. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
The device should not be used in an explosive environment. – The device should not be used in an atmosphere with chemically active substance. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
− set jumpers on the interface card to the ‘M’ position − configure the interface using the ALP software (Menu>Device>Configuration) akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
To create a variable for polling click the ‘+’ icon (see Fig. 4.4). To delete the selected variable click the ‘-’ icon. Fig. 4.3 Slave configuration in slave mode akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
‘Add interface’ (Fig. 4.5). Set the interface to Master, click RMB on it and add the slave device (Fig 4.6). See ALP Help for further instructions. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Page 13
(see 6.1.1). For outputs dp = 4 is fixed. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Page 14
This parameter will be ignored if the total polling time takes longer than the set value. Fig. 4.5 Master configuration in master mode akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Don’t set the jumpers on connectors XP2 and XP3 at the same time, otherwise the NOTICE device can be damaged. Fig. 4.5 akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Page 16
In this mode the firmware update can be forced. See ALP Help for further details about firmware update. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
. The next editable parameter will be displayed selected. The last changed parameter will be shown next time when the edit mode is entered. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Use the menu item Inputs>Digital>Filter to set the time constant for the debouncing filter in the range of 0…255 ms. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Page 19
Address • Polling cycle (ms) • Time-out (ms) • Retries, max. Time between frames (see 4.5 ‘Master mode’) akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Page 20
Information about connected extention modules. If there are no connected modules, the menu item is hidden. Fig. 5.2 Extension module connection Password Password can be set or changed. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Modbus as integer. Digital mode only Logical 0 – voltage 0…10 V Logical 1 – voltage 0…10 V akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Page 22
а Fig. 6.3 Input configuration jumper positions a) 0-10 V, b) 4-20 mA, c) digital mode, d) 0-4000 ohm akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Page 23
The greater the time constant is, the higher the damping of interference signal and the slower the response to rapid changes of the input value are. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
1.546745 will be displayed as 1.547 (rounded). When the value got changed to 110.478696, it will be displayed as 110.5. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Terminal assignment is given in Tables 7.1, 7.2 and layouts of terminal blocks are shown in Appendix B ─ Electrical connections for inputs and outputs are given in Fig. 7.2 – 7.7 akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Page 26
Different sensors can be connected within a group (AI1/AI2 or AI3/AI4). For example, AI1 can be configured as a digital input and AI2 as an analog input 4-20 mA. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Page 27
The load resistance RL may not exceed the range of 2…10 kohm. This type of output can be also powered from integrated voltage source 24V. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Page 28
Table 7.2 see Table 7.2 see Table 7.2 * Depending on device modification (PR200-230 or PR200-24) ** PR200-230 only akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
− remove all detachable parts of the terminal blocks − replace PR200 − connect detachable parts with existing wiring to the device Fig. 7.9 Quick replacement akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Spare parts must meet the technical requirements of the device manufacturer. Use only original spare parts from the manufacturer! akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Check the device for transport damage and completeness! Report the transport damage immediately to the shipper and akYtec GmbH! akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Appendix E. Connection to PC Appendix E. Connection to PC Fig. E.1 Connection to PC akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
7. The output current should be calculated from the measured output voltage and entered in the displayed field. Fig. F.4 Fig. F.5 akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
5. Perform the disassemble operations in reverse order to assemble the device. Fig. G.1 Front housing removing Fig. G.2 Top circuit board removing akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Page 44
Appendix G. Battery replacement Fig. G.3 Back side view of the top board akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
3. Cut an opening in the enclosure for the card terminal and mount the card on the mounting pins (Fig. H.1b). 4. Perform the disassemble operations in reverse order to assemble the device. Fig. H.1 akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...