13.1 Cleaning/decontamination

Cleaning of the METPOINT
one-way wipe, and mild, commercially available cleaner/soap.
For decontamination, spray the cleaner on an unused cotton cloth or one-way wipe and wipe the component
comprehensively. Effectuate subsequent drying using a clean cloth or via air drying.
In addition, the local hygiene provisions need to be observed.
Danger!
Compressed air/reaction products!
Risk of serious injury or death through contact with quickly or suddenly escaping compressed air
and through toxic, flammable, or potentially explosive reaction products.
Measures:
Only carry out cleaning measures when the system is pressureless.
Purge the respective plant component or pressure transducer prior to starting the maintenance works.
Immediately clean the removed components from media residues.
Warning!
Damage possible!
A too high degree of humidity and hard and pointed objects cause damage to the
pressure transducer and to the integrated electronic components.
Measures
Never clean with a soaked cloth.
Do not use pointed or hard objects for cleaning.
®
METPOINT
SP11
®
PRM SP11 must be undertaken using a slightly damp (not wet) cotton cloth or
Maintenance and calibration
21