Mechanical stresses
Vibration resistance/vibrations according to EN 60068-2-6
Mechanical shock resistance according to EN 60068-2-27
CE conformity
Pressure Equipment Directive
EMC Directive
EMC immunity to interference, industrial field
EMC emitted interference (emission), group 1, class B
CE labelling according to the EMC Directive 2004/108/EC
Electrical connections
Connector (cable box) according to EN 61076-2-101
Type of connection
Wire cross-section
Grommet
Protection class
1
For gases and fluids of fluid group 2, the requirements according to Article 3, Clause 3 (good engineering
practice) are met.
®
METPOINT
SP11
1
25 ... 2000 Hz, 20 g, sine
50 g, 11 ms, half-sine
97/23/EC
2004/108/EC
EN 61326-1 & EN 61326-2-3
EN 61326-1
M12 x1 (4-pole)
Screw terminals
2
max. 0.75 mm
(AWG 18)
4 ... 6 mm
IP 67 according to EN60529
Technical data