The following advice applies to the connection:
Shielding is implemented via the shield ring of the connector. The preconditions for proper shielding are that
the respective connector is made of metal and that the shield has the shape of a braid. The shielding must
be earthed at one end.
Connector, M12 x 1, 4-pole, a-coded
Arrangement of the poles plug
View transmitter side
The cable must be assembled as follows:
1.
Push the components of the plug connector over the cable
2.
Cut the cable jacket by 20 mm in length
3.
Cut the conductor sheath by 5 mm in length
4.
Introduce the cable into the connector according to the pin assignment
5.
Assemble/screw together the components of the connector
®
METPOINT
SP11
Arrangement of the poles - fe-
male connector
View female connector side
Electrical installation
Arrangement of the poles female
connector
View screwing side
19