  • Page 1 BE47 OPERATING MANUAL MULTIMETER...
  • Page 2: Table Of Contents

    • Do not remove any safety signs, stickers or labels from the device. Keep all safety signs, stickers and labels in legible condition. • Do not open the device with a tool. • Observe the storage and operating conditions as given in the Technical data chapter. multimeter BE47...
  • Page 3 To use the device for its intended use, only use accessories and To avoid damages to the device, make sure that the spare parts which have been approved by Trotec. correct measuring range is selected before carrying out a measurement.
  • Page 4: Information About The Device

    200 mV DC Red measuring probe up to 2000 mV DC Black measuring probe up to 20 V DC up to 200 V DC Fuses up to 600 V DC Battery compartment V/Ω/mA connection socket COM socket 10 A socket Rotary switch LC display multimeter BE47...
  • Page 5 This measuring device is designed for • 1 x Multimeter indoor use and complies with • 1 x Safety measuring lines with test probes overvoltage category CAT II 600 V / • 1 x 9 V monobloc battery CAT III 300 V, pollution level 2. • 1 x Getting started guide multimeter BE47...
  • Page 6: Transport And Storage

    2. Stick the label on the intended position at the rear of the Note device. Make sure that the surface of the device is dry and the device is switched off. 1. Remove the protective cover (1) from the device. 2. Loosen the screw at the battery compartment (5). multimeter BE47...
  • Page 7 ð The measured value is shown on the display. into the V/Ω/mA measuring socket. 4. Turn the rotary switch to the position that is the closest to the indicated value but does not fall below it. ð The measured value is shown on the display. multimeter BE47...
  • Page 8 ð If the measured value is 1, the diode is blocking. ð If OL is displayed with both polarities, the circuit is not closed. ð Measured values near 0 V indicate a short circuit in the circuit. multimeter BE47...
  • Page 9: Maintenance And Repair

    Display segments are only faintly visible or flicker: • The battery voltage is too low. Exchange the batteries immediately. The device displays implausible measured values: • The battery voltage is too low. Exchange the batteries immediately. multimeter BE47...
  • Page 10 Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...