Test Mode Operation - LED

Test Mode – Manual Operation/Manual Defrost
To enter the test mode, press ENERGY SAVER and ADJUST REFRIGERATOR pads simultaneously for 8 seconds.
The display panel will go blank. Press any pad within 15 seconds to initiate test mode.
If any pad is pressed within 15 seconds it will generate the following sequence:
1st press - Manual operation – Compressor and Fans (FF) Displayed
2nd press - Manual Defrost – Fresh Food Compartment (rd) Displayed
3rd press - Manual Defrost – FF and Frz Compartments (Fd) Displayed
4th press - Cancel – (Display Off) Normal Operation is restored after approximately 10 seconds.
Note: Test mode can also be canceled by removing power and then powering unit back up.
– 68 –