Mounting Of The Collector Or Heat Exchanger Pipes - Dimplex SVT 200KV Installation And Operating Instructions Manual

Advertisement

Available languages

Available languages

Mounting for systems with a maximum of 16 (2x8) circuits (with connection package AP SVT 16)
Fig. 5.3:
Mounting of a brine manifold with a maximum of 16 (2x8) circuits
5.2 Mounting of the collector or
heat exchanger pipes
The collector and the manifold are both equipped with ball valves
with which the individual collector or heat exchanger circuits can
Fig. 5.4:
Mounting of the brine manifold on the collector or heat exchanger
pipe or on the heat pump
www.dimplex.de
be completely shut off (e.g. in the event of a leakage). The PE
pipes (on site) of the collectors or heat exchangers can be di-
rectly mounted on the ball valves with the premounted clamping
ring fittings (connection diameter 32 mm). (Fig. 5.4 on page 5)
NOTE
The collector or heat exchanger pipes must be connected to the manifold
without tension.
5.2
GB-5