K Technical Data - Vaillant ecoTEC plus VU 446/5-5 (H-GB) Installation And Maintenance Instructions Manual

Hide thumbs Also See for ecoTEC plus VU 446/5-5 (H-GB):
Table of Contents

Advertisement

Appendix
Set values, G31 liquefied petroleum gas
CO₂ after 5 minutes
Checking
in full load mode with
during start-
front casing closed
up
Checking
after reset-
ting
CO₂ after 5 minutes
Checking
in full load mode with
during start-
front casing removed
up
Checking
after reset-
ting
Set for Wobbe index W₀
O₂ after 5 minutes in
Checking
full load mode with
during start-
front casing closed
up
Checking
after reset-
ting
K
Technical data
Technical data – Heating
Maximum heating flow temperature (default setting – D.71)
Range for the heating flow temperature control
Maximum permissible pressure (PMS)
Safety discharge of expansion relief valve
Nominal water flow (ΔT = 20 K)
Approximate value for the condensate volume (pH value between
3.5 and 4.0) at 50/30 °C
Maximum heat output (factory setting – D.000)
Technical data – Power/heat input (G20)
Effective output range (P) at 50/30 °C
Heat output range (P) at 60/40 °C
Effective output range (P) at 80/60 °C
Maximum heat input – heating (Q max.)
Minimum heat input – heating (Q min.)
Technical data – Power/heat input (G31)
Effective output range (P) at 50/30 °C
Effective output range (P) at 80/60 °C
Maximum heat input – heating (Q max.)
Minimum heat input – heating (Q min.)
Technical data – General
Gas category
Diameter of the gas pipe at the product outlet
Diameter at the outlet of the gas compression fitting, outside thread
62
VU 446/5-5
VU 606/5-5
(H-GB)
(H-GB)
9.9 ± 1.0 vol.
10.1 ± 1.0 vol.
%
%
9.9 ± 0.3 vol.
10.1 ± 0.3 vol.
%
%
9.7 ± 1.0 vol.
9.9 ± 1.0 vol.
%
%
9.7 ± 0.3 vol.
9.9 ± 0.3 vol.
%
%
21.3 kW⋅h/m³
21.3 kW⋅h/m³
5.9 ± 1.8 vol.
5.5 ± 1.8 vol.
%
%
5.9 ± 0.5 vol.
5.5 ± 0.5 vol.
%
%
Installation and maintenance instructions ecoTEC plus 0020261389_02
VU 446/5-5 (H-GB)
75 ℃
30 ... 80 ℃
0.4 MPa
(4.0 bar)
0.4 MPa
(4.0 bar)
1,900 l/h
4.5 l/h
Auto
VU 446/5-5 (H-GB)
8.7 ... 48.0 kW
8.5 ... 46.6 kW
7.8 ... 44.1 kW
45.2 kW
8.1 kW
VU 446/5-5 (H-GB)
8.6 ... 46.6 kW
7.8 ... 44.0 kW
45.2 kW
8.1 kW
VU 446/5-5 (H-GB)
II2H3P
25 mm
1"
VU 606/5-5 (H-GB)
75 ℃
30 ... 80 ℃
0.4 MPa
(4.0 bar)
0.4 MPa
(4.0 bar)
2,500 l/h
5.6 l/h
Auto
VU 606/5-5 (H-GB)
12.2 ... 63.5 kW
11.8 ... 61.7 kW
11.0 ... 58.7 kW
60.0 kW
11.3 kW
VU 606/5-5 (H-GB)
12.0 ... 62.1 kW
11.1 ... 58.4 kW
60.0 kW
11.3 kW
VU 606/5-5 (H-GB)
II2H3P
25 mm
1"

Hide quick links: