Table 4 — Electrical Data (Units Without Optional Convenience Outlet) (cont)
VOLTAGE
NOMINAL
UNIT
RANGE
No. 1
VOLTAGE
SIZE
(3 Ph,
50PG
60 Hz)
Min
Max RLA LRA RLA LRA RLA LRA
208/230
187
253
32.1
240
24
460
414
506
15.4
110
See Legend and Notes on page 15.
COMPRESSOR
OFM
No. 2
No. 3
FLA
Qty
Hp
(ea)
32.1
240
6
0.25
1.5
15.4
110
6
0.25
0.7
ELECTRIC
POWER
IFM
HEAT
EXHAUST
kW
FLA
Hp
FLA
Qty Hp
3.7
10.6/9.6
2
1
5
16.7/15.2
2
1
7.5
24.2/22
2
1
10
30.8/28
2
1
3.7
10.6/ 9.6
2
1
5
16.7/15.2
2
1
19/25
52/60
7.5
24.2/22
2
1
10
30.8/28
2
1
3.7
10.6/9.6
2
1
5
16.7/15.2
2
1
38/50
104/120
7.5
24.2/22
2
1
10
30.8/28
2
1
3.7
10.6/9.6
2
1
5
16.7/15.2
2
1
56/75†
156/180
7.5
24.2/22
2
1
10
30.8/28
2
1
3.7
4.8
2
1
5
7.6
2
1
7.5
11
2
1
10
14
2
1
3.7
4.8
2
1
5
7.6
2
1
25
30
7.5
11
2
1
10
14
2
1
3.7
4.8
2
1
5
7.6
2
1
50
60
7.5
11
2
1
10
14
2
1
3.7
4.8
2
1
5
7.6
2
1
75
90
7.5
11
2
1
10
14
2
1
14
POWER SUPPLY
WITH OPTIONAL
POWER SUPPLY
HACR BREAKER
FLA
MCA
MOCP*
MCA
MOCP
(ea)
92/91
100/100
92/92
100/100
5.9
104/103
125/125
104/104
125/125
98/ 96
100/100
98/ 98
100/100
5.9
110/108
125/125
110/110
125/125
105/103
125/125
105/105
125/125
5.9
117/115
125/125
117/117
125/125
112/109
125/125
112/112
125/125
5.9
124/121
150/150
124/124
150/150
92/91
100/100
92/ 92
100/100
5.9
104/103
125/125
104/104
125/125
98/ 96
100/100
98/98
100/100
5.9
110/109
125/125
110/110
125/125
105/103
125/125
105/105
125/125
5.9
117/117
125/125
117/117
125/125
112/110
125/125
112/112
125/125
5.9
124/125
150/150
125/125
150/150
143/132
150/150
143/143
150/150
5.9
158/147
175/150
158/158
175/175
151/139
175/150
151/151
175/175
5.9
166/154
175/175
166/166
175/175
160/148
175/150
160/160
175/175
5.9
175/162
200/175
175/175
200/200
169/155
175/175
169/169
175/175
5.9
183/170
200/175
183/183
200/200
92/ 91
100/100
92/ 92
100/100
5.9
104/103
125/125
104/104
125/125
98/ 96
100/100
98/ 98
100/100
5.9
110/108
125/125
110/110
125/125
105/103
125/125
105/105
125/125
5.9
117/115
125/125
117/117
125/125
112/109
125/125
112/112
125/125
5.9
124/121
150/150
124/124
150/150
44
50
44
50
3.1
50
60
50
60
46
60
46
60
3.1
53
60
53
60
50
60
50
60
3.1
56
60
56
60
53
60
53
60
3.1
59
60
59
60
44
50
44
50
3.1
51
60
51
60
47
60
47
60
3.1
55
60
55
60
51
60
51
60
3.1
59
60
59
60
55
60
55
60
3.1
63
70
63
70
66
80
66
80
3.1
74
80
74
80
70
80
70
80
3.1
77
80
77
80
74
80
74
80
3.1
82
90
82
90
78
90
78
90
3.1
85
90
85
90
96
100
96
100
3.1
104
110
104
125
100
110
100
125
3.1
107
125
107
125
104
125
104
125
3.1
112
125
112
125
108
125
108
125
3.1
115
125
115
125
DISCONNECT
SIZE
FLA
96/95
110/109
103/102
117/115
112/109
126/123
120/116
133/130
96/ 95
110/109
103/102
117/115
112/109
126/123
120/116
133/130
132/149
145/163
139/155
152/169
147/163
161/177
155/170
169/184
96/ 95
110/109
103/102
117/115
112/109
126/123
120/116
133/130
46
53
49
56
53
60
56
63
46
53
49
56
53
60
56
63
75
82
78
85
82
89
85
92
109
116
112
119
116
123
120
127