Operating Data; Mechanics; Connection - LinMot S01-24/500 Installation Manual

Power range 480 w
Table of Contents

Advertisement

Installation Guide Power Supply
Safety / Standards
EMC
Mains feedback / PFC
Flicker
Interference immunity
ESD
Electrical fields
Burst
Surge
HF Immunity
Voltage drop
Interference emission
Weight

4 Operating data

Temperature range
-25°C...70°C (integral, temperature-regulated fan, sucking in air from below)
Derating
3% / K at +60°C (see diagram chapter 7)
Due to the integrated fan, the SPH500 can be installed in any position. The passage of air
must not be obstructed by installation.
The distance to the air vents must be at least 20 mm. Fire protection must be ensured
via the outer casing system.
Protect the products against moisture, humidity, condensation and dirt.

5 Mechanics

5.1 Connection

Mains input:
4-pol terminal
1.5 - 4/6 mm² strand / wire
tightening torque 0.6 - 0.7 Nm
Load output:
4-pol terminal
1.5 - 4/6 mm² strand / wire
tightening torque 0.6 - 0.7 Nm
Control signals: 4-pol terminal, pluggable
0.1 - 0.5 mm² strand / wire
Page 6 / 12
IEC60950 / UL60950 / UL508 / CSA22.2-60950 / CSA22.2-107.1 / IP20,
safety class 1 / pollution degree 2
EN 61000-3-2 Class A only with ext. PFC 12mH/4, 5A/230VAC
EN 61000-6-2 Industrial generic standard
EN 61000-4-3 noise level 10V/m (Krit. A)
EN 61000-4-4 4KV (Krit.A)
EN 61000-4-5 4/2KV (Krit.A)
EN 61000-4-6 noise level 10V (Krit.A)
EN 61000-6-4 Industrial generic standard
EN 55011 Class B, Radiation depends on assembly
Power range 480 W
EN 61000-3-3
EN 61000-4-2 8/15KV
EN 61000-4-11
1.0 kg