If the version in the decoder is older than the version loaded into the ICD‐HP,
and you wish to update the decoder, press Next . This will show the version
of the "bootloader" program, which actually loads the firmware into the
decoder.
Press Next again to continue, and the firmware update will begin. A status
bar will show the progress of the download.
It will take several minutes to update a decoder's firmware. Do not disconnect the decoder during this update! The
firmware update should always be allowed to complete, once it has begun.
The update will not erase the decoder output station addresses. If the decoder is used as a Pump, this information will
also be retained.
If the decoder is a Sensor Decoder, it will automatically receive the Sensor
Decoder firmware, and the address and port settings will be retained.
A status screen will announce when the update is complete, and verify the
new version number.
24
DECODER UPDATE
----------------------
Update Progress...
DECODER UPDATE
----------------------
!Complete!
Dec Type:
X-Station
Station #:
###
Serial #:
########
Version:
#.##.###