Hunter ICD-HP Owner's Manual And Operating Instructions page 20

Handheld programmer for hunter icd decoders
Table of Contents

Advertisement

Connect to any decoder to view status, for identification and diagnostics. This can be used with either installed decoders, 
or disconnected decoders that are powered through the ICD‐HP power leads. 
From the Main Menu, select Decoder Programming with the Next   button. Move the pointer with the up/down arrows 
to Get Decoder Status, and press Next   again to select. The ICD‐HP will attempt to communicate with the decoder. 
When a decoder is found, the status will be displayed. 
Station Decoders: If the decoder is a Station Output decoder, the display will 
show the following information. 
Dec State: Can be Normal, Fault, or Damaged. 
Normal: Decoder is responding correctly. 
Fault: Decoder output wires are shorted or solenoid coil is shorted. 
This does not indicate a problem with the decoder! Check field 
wiring and solenoid. 
Damaged: There is a problem with the decoder, and it should be replaced. Damaged indicates the decoder is 
"leaking" voltage on the outputs when it should be off. 
20 
 
DECODER STATUS
----------------------
Dec State:
Normal
Current:
167mA
Output #: 1 2 3 4 5 6
Solenoid: Y Y Y Y Y N
Active :
Y Y Y Y N N
Normal Decoder has 5 solenoids detected, 
with 4 stations running (Active). 