LOADING AND STARTING THE FIREBOX
HOT START
A hot start uses the coals from the previous days burning operation. Depending on
how much ash is in the unit, a hot start can usually be done only once before the unit
will need to be emptied. The more ash in the FireBox that you start with the LESS
room you have for burning new materials. Hot starting may not be practical for the
BurnBoss due to its smaller size.
First, insure there are enough coals remaining to generate enough heat to get the new
waste materials burning. You CANNOT add an accelerant, if the waste materials do
not light, as that would be too dangerous. If the material does not light, the FireBox
must be emptied before trying a cold start with the use of an accelerant.
DANGER: Do not
unexpectedly and cause injury or death.
.
HOT START LIGHTING
Similarly to a cold start you begin with your best and most burnable materials.
1)
Load the FireBox to about one third or half way with the "Good Wood". The
wood should begin burning as soon as you start loading.
2)
Start the engine and run at approximately 1,400 RPM. This should help fan the
flames and spread the fire. If you experience heavy smoke then reduce the
RPM's. Be cautious not to "blow out" the fire.
3)
As the fire begins to heat up, increase the RPM's.
BurnBoss Series Air Curtain Burner (Kubota Z482-E3 Engine)
use an accelerant for a Hot Start, as it may ignite
Page 20 of 27
Air Burners, Inc.
OPERATING MANUAL
(Vers. 08.08.2017)

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Air Burners BurnBoss T22

This manual is also suitable for:

Burnboss t24

Table of Contents