Sarstedt SMC 6 Instruction Manual

Sarstedt SMC 6 Instruction Manual

With horizontal rotor 6 x

Advertisement

Instruction Manual
Centrifuge SMC 6
with horizontal rotor 6 x
SARSTEDT No.: 90.184.550

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMC 6 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sarstedt SMC 6

  • Page 1 Instruction Manual Centrifuge SMC 6 with horizontal rotor 6 x SARSTEDT No.: 90.184.550...
  • Page 2: Table Of Contents

    ..............15 10. Index ..............................15 Copyright: The copyright for these operating instructions lies with SARSTEDT AG & Co. The instructions are only intended Contamination questionnaire ........................16 for use by operating personnel and for the purchaser of the device. Reproduction or distribution of this publication, in whole or in part, is not permitted without the written consent of SARSTEDT AG &...
  • Page 3: Explanation Of Symbols

    Operating Instructions Centrifuge SMC 6 Operating Instructions Centrifuge SMC 6 3.1. Explanation of symbols The device may not be used: These operating instructions contain important symbols to indicate dangers and possible operating errors. • in explosion-hazarded areas. • with flammable or explosive materials or substances that may precipitate strong reactions with one another.
  • Page 4: Other Information

    SMC 6 is equipped with a “0 rpm” lid locking system. This safety system keeps the lid closed at all times (even in the event of a power failure) and ensures that the lid can be unlocked only when the rotor has •...
  • Page 5: Commencing Operation

    Operating Instructions Centrifuge SMC 6 Operating Instructions Centrifuge SMC 6 6.3. Commencing operation 7. Operation 7.1. Control elements Caution before first use! • Check that the actual supply voltage corresponds with the stated supply voltage. • Comply with the permitted ambient conditions for the machine.
  • Page 6: Loading The Rotor

    Operating Instructions Centrifuge SMC 6 Operating Instructions Centrifuge SMC 6 7.3. Loading the rotor 8. Technical data Machine data The centrifuge must be evenly loaded for it to function properly. Apparatus: Centrifuge SMC 6 To ensure even loading, comply with the following rules when loading the...
  • Page 7: Maintenance And Servicing

    The repeated inspections in accordance with accident prevention regulations (UW) published as „Technical Rule Example for a disinfectant: BGR 500” do not apply to the models of Series SMC 6 and LC24 as these conform to the following criteria: The following aqueous solution can be used as a disinfectant: 25 g ethanol 96 %, 35 g 1-propanol, 0,1 g glyoxal ad 100 g aqua dest.
  • Page 8: Access To The Rotor Chamber During A Power Failure

    Operating Instructions Centrifuge SMC 6 Operating Instructions Centrifuge SMC 6 9.5. Programming 9.6. Access to the rotor chamber during a power failure How to check program parameter settings) In the event of a power failure, it may be impossible to unlock 1.
  • Page 9: Contamination Questionnaire

    Contamination questionnaire for repair orders Dear Customer, Please complete the contamination questionnaire before you return the instrument to the service department of DESAGA GmbH / SARSTEDT-GRUPPE or to your local SARSTEDT sales representative for maintenance or repair. Firm: Department: Town:...

Table of Contents