3.
Adjust the links if necessary, see Figure 12.
WARNING!
Spring power. Check the function of the spring and spring holder.
4.
Check that the suction capacity in the hood is sufficient.
6.1

Adjusting the links

See Figure 12. Recommended at least once a year. Use necessary safety
equipment.
A. Adjust the inner link.
B. Adjust the knee link.
C1. Loosen the bellows.
C2. Unscrew the ball joint from the hood.
C3. Remove the bellows.
C4. Loosen the two socket head cap screws.
C5. Tighten the ball joint using two adjustable spanners.
C6. Remount the ball joint at the hood and test the hood movement.
If necessary, tighten the ball joint still more.
C7. Tighten the two socket head cap screws.
C8. Unscrew the ball joint from the hood. Refit the bellows. Fasten the
bellows at the outer arm cover. Fasten the ball joint at the hood.
NOTE!
The nut securing the hood must be tightened securely.
6.2

Spare parts

Installation, repair and maintenance work is to be carried out by qualified
personnel using only original Nederman spare parts. Contact your nearest
authorized distributor or Nederman for advice on technical service.
Ordering spare parts
When ordering spare parts always state the following:
Part number and control number (see the product identification plate).
Detail number and name of the spare part (see www.nederman.com).
Quantity of the parts required.
7

Recycling

The product has been designed for component materials to be recycled.
Its different material types must be handled according to relevant local
regulations. Contact the distributor or Nederman if uncertainties arise when
scrapping the product at the end of its service life.