Download Print this page

Troubleshooting - Pro'sKit SS-956 User Manual

Smart rework station with vacuum pickup

Advertisement

20~100)
NOTE:
1. The tube cannot be bent, or it may influence airflow and suction.
2. Absorbed object surface should be smooth in order to be sucked.
3. Pay attention to prevention of ESD, so as not to damage the device
4. Before using vacuum pickup pen, turn off the hot air gun.
5. Do not overexert while fixing nozzle, use pliers to pull the nozzle, or screw breech block too
tight.
6. Be careful when working with high temperature.
7. Do not use this product near flammable gas, paper, or other flammable things.
8. The temperature of nozzle and hot air is very high and could injury user. Don't touch the
heating part or blow the hot air to body
9. Use hot air to solder is feasible, but it could cause the problem of solder link or solder ball, for
which we highly recommend you to check it carefully.
10. For the new machine, it might occur smoke in a short time when it starts to work in the first time
due to heating insulation material inside the handle, and this is normal.
Trouble Shooting
Warning:
Before checking the inside of the SS-956 or replacing parts, be sure to disconnect the power plug.
Failure to do so may result in electric shock.
Defect Situation
Dead, doesn't work
Hot air gun - Air
temperature doesn't
heat up
Hot air gun - Airflow
level abnormal
Suction function
abnormal
Display shows
abnormal
Temperature unit
display abnormal
Possible Problem
Blown fuse
Display S-E, plug doesn't connect
properly
Calibration parameter changes
Heating element is broken
Internal pipe is obstructed or loose
which causes air leakage
Pump securing screws are not
loosened
Tube is broken or not installed properly
Suction cup is aging or not installed
properly
Transportation causes inside PCB
board connect improperly
Input voltage lower than standard
request
IC broken
Solution
Change new fuse
SS-956E(110V) : 250V / 8A
SS-956B(220V) : 250V / 5A
SS-956H(220V) : 250V / 5A
Reconnect the plug of hot air gun
(as Fig-22)
Calibrate again
Replace heating element
5SS-989NE-H(110V)
5SS-989NB-H(220V)
Clear the internal pipe, reconnect
the pipe tightly.
Loosen the pump securing screw,
which on the bottom of rework
station.
Change new tube or re-install tube
Change new suction cup or
re-install suction cup
Open the case, reconnect the PCB
board
Check with local power service
provider
Contact vendor for repair
9

Advertisement

loading