H3C S7500E Series Configuration Manual page 28

Hide thumbs Also See for S7500E Series:
Table of Contents

Advertisement

As shown in
Figure
1-9, if the IRF virtual device in active state fails due to exceptions (a member fails or
link failure occurs, for example) before the IRF link is recovered, enable IRF virtual device 2 (in the
recovery state) to change the state of IRF virtual device 2 from recovery to active, and repair the IRF
links. Then, the two IRF virtual devices merge when the IRF link failure is recovered. The following are
the operation steps:
1)
Execute the mad restore command on IRF virtual device 2 (in the recovery state) to change its
state from recovery to active.
2)
Repair IRF virtual device 1 and IRF links, and then reboot IRF virtual device 1.
After the reboot, IRF virtual device 1 and IRF virtual device 2 merge and the IRF virtual device recovers.
Figure 1-9 Recover IRF member devices (approach II)
Follow these steps to manually restore the device in the recovery state to the active state:
To do...
Enter system view
Restore the devices in the
recovery state to the active state
Use the command...
system-view
mad restore
1-21
Remarks
Required